Calculation of Response matrix of a BSS with 6LiI scintillator



Document title: Calculation of Response matrix of a BSS with 6LiI scintillator
Journal: Revista mexicana de física
Database: PERIÓDICA
System number: 000336806
ISSN: 0035-001X
Authors: 1
2
2
1
2
3
3
3
Institutions: 1Universidad Autónoma de Zacatecas, Unidad Académica de Estudios Nucleares, Zacatecas. México
2Universidad Politécnica de Madrid, Departamento de Ingeniería Nuclear, Madrid. España
3Universidad de Valladolid, Departamento de Física Teórica, Atómica y Optica, Valladolid. España
Year:
Season: Feb
Volumen: 54
Pages: 57-62
Country: México
Language: Inglés
Document type: Conferencia o discurso
Approach: Experimental, aplicado
Spanish abstract Se calculó la matriz de respuesta de un espectrómetro de Esferas de Bonner utilizando los códigos Monte Carlo MCNP 4C y MCNPX 2.4.0. El detector de neutrones térmicos del espectrómetro es un centellador cilindrico, 0.4 cm X 0.4 cm, de 6LiI, que se ubica en el centro de esferas de polietileno. La respuesta se obtuvo para esferas cuyo diametro es 0, 2, 3, 5, 8, 10 y 12 pulgadas y para fuentes monoenergéticas de neutrones de 2.50E(–8) to 100 MeV. La matriz se calculó para 23 fuentes monoenergéticas, las funciones de respuesta se interpolaron a 51 energías que se compararon con las correspondientes reportadas en la literatura. Se encontró que ambas matrices son coincidentes, excepto para neutrones de baja y alta energía; esta diferencia es atribuida a las condiciones de irradiación utilizadas en ambos estudios y a las secciones eficaces
English abstract The response matrix of a Bonner sphere spectrometer was calculated using MCNP 4C and MCNPX 2.4.0 codes. As thermal neutron detector a 0.4 cm x 0.4 cm 6 LiI which is located at the center of a set of polyethylene spheres. The response was calculated for 0, 2, 3, 5, 8, 10, and 12 inches–diameter polyethylene spheres for neutrons whose energy goes from 2.50E(–8) to 100 MeV. The response matrix was calculated for 23 neutron energies, the response functions were energy–interpolated to 51 neutron energies and were compared with a matrix response reported in the literature, in this comparison both response matrices are in agreement. The main differences were found in the bare detector and are attributed to the irradiation conditions and cross sections, for the other detectors the differences are due to the cross sections libraries
Disciplines: Física y astronomía
Keyword: Física nuclear,
Espectrómetro de esferas de Bonner,
Centelleadores,
Matriz de respuesta,
Modelos de Montecarlo
Keyword: Physics and astronomy,
Nuclear physics,
Bonner sphere spectrometer,
Scintillators,
Response matrix,
Monte Carlo model