Comparison of clinical outcomes regarding the use of titanium-nitride-oxide-coated stents (Titan) versus zotarolimus-eluting stents (Endeavor) in patients with ST-segment elevation myocardial infarction (STEMI): An experience from a Cardiac Center-Third care level



Document title: Comparison of clinical outcomes regarding the use of titanium-nitride-oxide-coated stents (Titan) versus zotarolimus-eluting stents (Endeavor) in patients with ST-segment elevation myocardial infarction (STEMI): An experience from a Cardiac Center-Third care level
Journal: Revista mexicana de cardiología
Database: PERIÓDICA
System number: 000431069
ISSN: 0188-2198
Authors: 1
1
1
1
1
Institutions: 1Instituto Mexicano del Seguro Social, Unidad Médica de Alta Especialidad 34, Monterrey, Nuevo León. México
Year:
Season: Ene-Mar
Volumen: 29
Number: 1
Pages: 13-26
Country: México
Language: Inglés
Document type: Artículo
Approach: Analítico, descriptivo
Spanish abstract Introducción: A nivel internacional, la eficacia y la seguridad de los stents bioactivos Titan se han evaluado en comparación con los stents liberadores de fármacos (su sigla en inglés es DES) de segunda generación en pacientes con síndrome coronario agudo. Sin embargo, en nuestro campo, no hay suficiente información acerca de sus resultados de seguimiento a corto plazo o de un año cuando se compara con una endoprótesis liberadora de fármacos de segunda generación en el infarto de miocardio por elevación del segmento ST (STEMI). Objetivo: Evaluar y comparar los resultados clínicos inmediatos, en el hospital y a un año de uso del stent Titan frente a stent Endeavor en pacientes con infarto de miocardio por elevación del segmento ST. Material y métodos: Se realizó un estudio observacional descriptivo, comparativo, longitudinal, retrospectivo y observacional en pacientes con el síndrome coronario agudo de infarto de miocardio por elevación del segmento ST que fueron sometidos a angioplastias primarias, farmacoinvasivas y de rescate, utilizando un stent Titan contra el stent Endeavor. Puntos primarios: eventos cardiacos adversos mayores (MACE), muerte, infarto de miocardio, necesidad de revascularización de la lesión objetivo (TLR). Revascularización del vaso objetivo (TVR), evento cerebrovascular (CVE) y trombosis del stent. Puntos secundarios: Tiempo de uso de la terapia antiplaquetaria dual (DAPT). Resultados: De enero de 2011 a diciembre de 2014 se examinaron 256 pacientes con infarto de miocardio por elevación del segmento ST. Fueron tratados con un stent bioactivo de Titan (135 pacientes) o un stent de Endeavor (121 pacientes). No hubo diferencias significativas relacionadas con los eventos cardiacos adversos mayores, muerte, infarto de miocardio, trombosis de stent o evento cerebrovascular, ni en el hospital ni en el seguimiento de un año. Se observaron más pacientes en la clasificación Killip-Kimball 3-4 en el grupo de ste
English abstract Introduction: Internationally, the Titan bioactive stent efficacy and safety have been evaluated against second-generation drug-eluting stents (DES) in patients with acute coronary syndrome. In our field, however, there is not enough information about its short-term or one-year follow-up outcomes when compared with a second-generation drug-eluting stent in ST-segment elevation myocardial infarction (STEMI). Objective: To evaluate and compare immediate, in-hospital and one-year use clinical outcomes of the Titan stent versus Endeavor stent in patients with ST-segment elevation myocardial infarction. Material and methods: A descriptive, comparative, longitudinal, retrospective, observational study was performed in patients with ST-segment elevation myocardial infarction type acute coronary syndrome who were subjected to primary, pharmacoinvasive and rescue angioplasties, using a Titan stent against Endeavor stent. Primary points: major adverse cardiac events (MACEs), death, myocardial infarction, need for target lesion revascularization (TLR), target vessel revascularization (TVR), cerebrovascular event (CVE) and stent thrombosis. Secondary points: Dual antiplatelet therapy (DAPT) usage time. Results: 256 patients with ST-segment elevation myocardial infarction were examined from January 2011 to December 2014. They were treated with a Titan bioactive stent (135 patients) or Endeavor stent (121 patients). There were no significant differences related to major adverse cardiac events, death, myocardial infarction, stent thrombosis or cerebrovascular event, either in-hospital or one-year follow-up. More patients were observed in the Killip-Kimball 3-4 classification in Endeavor stent group versus patients in Titan stent group (62.2% versus 42.2%, respectively, p = 0.010). A greater pre-PTCA (Percutaneous Transluminal Coronary Angioplasty) TIMI (Thrombolysis in Myocardial Infarction) 0-1 flow rate was also observed (90.9% in Endeavor stent group versus 79
Disciplines: Medicina
Keyword: Sistema cardiovascular,
Terapéutica y rehabilitación,
Stent coronario,
Angioplastia,
Liberación de fármacos,
Infarto al miocardio,
Trombosis,
México
Keyword: Cardiovascular system,
Therapeutics and rehabilitation,
Angioplasty,
Coronary stent,
Drug delivery,
Myocardial infarction,
Thrombosis,
Mexico
Full text: Texto completo (Ver HTML) Texto completo (Ver PDF)