Improvement of the third harmonic based stator ground fault protection for high resistance grounded synchronous generators



Document title: Improvement of the third harmonic based stator ground fault protection for high resistance grounded synchronous generators
Journal: Revista Facultad de Ingeniería. Universidad de Antioquia
Database: PERIÓDICA
System number: 000333956
ISSN: 0120-6230
Authors: 1
1
1
Institutions: 1Universidad Tecnológica de Pereira, Programa de Ingeniería Eléctrica, Pereira, Risaralda. Colombia
Year:
Season: Mar
Number: 52
Pages: 215-225
Country: Colombia
Language: Inglés
Document type: Artículo
Approach: Experimental, aplicado
Spanish abstract En éste artículo se presenta una comparación y una propuesta de mejoramiento de tres diferentes métodos de protección del 100% del estator en el caso de fallas a tierra, aplicados a generadores síncronos aterrizados mediante una alta resistencia. Los tres métodos están basados en las mediciones de tercer armónico de tensión en el neutro, en los terminales de la máquina y en la relación de las dos medidas anteriores. De los resultados obtenidos en generador síncrono real, se puede apreciar que el esquema basado en la relación de las tensiones de tercer armónico medido en los terminales y en el neutro es la mejor alternativa, en el caso de utilizar la estrategia de umbrales de tensión. Sinembargo, mediante al utilización de una estrategia propuesta basada en una lógica para alarma y disparo, se pueden apreciar notables mejoras en la capacidad de detección de fallas a tierra de alta impedancia. Finalmente, este trabajo puede contribuir al desarrollo de elementos de protección útiles para detectar fallas a tierra en los devanados del estator de un generador síncrono. Aunque una primera falla normalmente no causa ningún problema, ésta tiene que ser atendida prontamente antes que una segunda falla pueda causar graves daños en la máquina y su consiguiente salida del servicio
English abstract This paper shows a comparison and a proposed improvement of three different approaches based on the measurements of the third harmonic of voltage which are aimed to obtain a 100% protection of the stator winding in the case of ground faults in high resistance grounded synchronous generators. These three different methods are based in voltage measurements at the neutral and terminal connections, and also in the ratio of these measurements. From the results obtained in a real synchronous generator there are advantages of the scheme based on the ratio of the voltages measured at terminals and neutral, in the case of using the voltage threshold strategy. However, by using the proposed alarm-trip logic, remarkable improvements could be obtained in the case of detecting high impedance ground faults. Finally, this work may help to develop useful protective devices which detect ground faults at the synchronous generator stator windings. Although a first fault normally does not cause any problem, this have to be removed before the occurrence of a second ground fault which could cause severe machine damages and the consequent outage
Disciplines: Ingeniería
Keyword: Ingeniería eléctrica,
Energía eléctrica,
Fallas eléctricas,
Generadores sincrónicos,
Tercer armónico,
Estator
Keyword: Engineering,
Electrical engineering,
Electric energy,
Electric failure,
Synchronous generators,
Third harmonic,
Stator