Endotoxins in surgical instruments of hip arthroplasty



Document title: Endotoxins in surgical instruments of hip arthroplasty
Journal: Revista da Escola de Enfermagem da USP
Database: PERIÓDICA
System number: 000403942
ISSN: 0080-6234
Authors: 1
1
1
1
2
3
4
4
Institutions: 1Universidade Federal de Minas Gerais, Escola de Enfermagem, Belo Horizonte, Minas Gerais. Brasil
2Centro Universitario de Belo Horizonte, Instituto de Engenharia e Tecnologia, Belo Horizonte, Minas Gerais. Brasil
3Universidade Federal de Minas Gerais, Hospital Risoleta Tolentino Neves, Belo Horizonte, Minas Gerais. Brasil
4Universidade Federal de Minas Gerais, Instituto de Ciencias Biologicas, Belo Horizonte, Minas Gerais. Brasil
Year:
Season: Jun
Volumen: 50
Number: 3
Pages: 405-410
Country: Brasil
Language: Inglés
Document type: Artículo
Approach: Analítico, descriptivo
Spanish abstract Investigar las endotoxinas en instrumentales quirúrgicos esterilizados empleados en artroplastias de la cadera. MÉTODO Estudio exploratorio, descriptivo, desarrollado en un hospital público de enseñanza. Fueron seleccionados seis tipos de instrumentales, a saber: raspa de acetábulo, raspa femoral, sacacorchos (para extraer la cabeza femoral), gubia quirúrgica, fresa femoral y cabeza femoral de prueba. La selección se hizo desde el análisis de la dificultad para la retirada de residuos de sangre y hueso durante la limpieza. La muestra estuvo constituida de 60 instrumentales quirúrgicos, que fueron puestos a prueba para endotoxinas en tres momentos diferentes. Se utilizó el método de gelificación (Gel-clot) Lisado de Amebocitos de Limulus (LAL) Endosafe(tm). RESULTADO Hubo formación de gel consistente con análisis positivo en ocho instrumentos, lo que corresponde a el 13,3%, siendo cuatro raspas femorales y cuatro fresas femorales. CONCLUSIÓN Fueron detectadas endotoxinas en cantidad ≥0,125 UE/mL en el 13,3% de los instrumentos probados
English abstract To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method) was used. RESULT There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. CONCLUSION Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested
Disciplines: Medicina
Keyword: Cirugía,
Microbiología,
Ortopedia,
Instrumental quirúrgico,
Esterilización,
Endotoxinas,
Artroplastia,
Cadera
Keyword: Medicine,
Microbiology,
Surgery,
Orthopedics,
Surgical instruments,
Sterilization,
Endotoxins,
Arthroplasty,
Hip