Evaluación de las características microbiológicas y fisicoquímicas del agua sometida a procesos de esterilización en autoclaves a vapor



Document title: Evaluación de las características microbiológicas y fisicoquímicas del agua sometida a procesos de esterilización en autoclaves a vapor
Journal: Respuestas
Database: PERIÓDICA
System number: 000420878
ISSN: 2422-5053
Authors: 1
1
1
1
Institutions: 1Universidad de Santander, Bucaramanga, Santander. Colombia
Year:
Season: Jul-Dic
Volumen: 22
Number: 2
Pages: 59-66
Country: Colombia
Language: Español
Document type: Artículo
Approach: Aplicado, descriptivo
Spanish abstract El presente trabajo describe las características fisicoquímicas y microbiológicas del agua antes y después de ser sometidas a un proceso de esterilización en un autoclave a vapor con carga de instrumental y paquetes de vestuario quirúrgico, con el fin de establecer el potencial para el posterior sin causar ningún efecto en la validez de la carga por ciclo. Las mediciones fueron descritas por separado, antes del primer proceso de esterilización, durante la etapa de descarga y de la entrada del agua que fue utilizada para dicho proceso. Para el desarrollo del proceso, se realizaron tres tomas de muestras con agua de osmosis y 5 correspondientes al agua directamente de grifo; posterior a cada toma de muestra se tomaron en cuenta los parámetros de esterilización, resoluciones ambientales y microbio-lógicas. Los resultados obtenidos mostraron significancia en los diferentes puntos de toma de muestras que llevaron a concluir alteraciones en el agua de osmosis en los diferentes puntos de muestra (entrada, chaqueta y descarga) del autoclave en lo relacionado a las características fisicoquímicas del agua obtenida de los puntos analizados del autoclave. Adicionalmente se observó presencia de coliformes totales y fecales, aerobios mesófilos que indicaron que el agua no es apta para recirculación dentro del autoclave
English abstract This study describes the physicochemical and microbiological characteristics of the water before and after being subjected to sterilization process in steam autoclave loaded with in-strumental and surgical clothes, in order to establish its potential use without causing any effect on the validity of the charging cycle. Measurements were described separately be-fore the first sterilization process, during the discharge stage and at the entry of water that was used for this process. For the development of the process, three samples were taken with osmosis water and five directly from tap water; after each sample the parameters of sterilization, and environmental and microbiological resolutions were taken into account. The results showed significance in the different sampling points leading to conclude dis-turbances in the osmosis water at different sampling points (input, jacket and discharge) of the autoclave regarding the physicochemical characteristics of water obtained from the points analyzed in the autoclave. Additionally, presence of total and fecal coliforms was observed as well as aerobic mesophilic bacteria indicating that water is not suitable for recirculation within the autoclave
Portuguese abstract O presente trabalho descreve as características físico-químicas e microbiológicas da água antes e depois de ser submetido a um processo de esterilização em uma autoclave de vapor carregada com instrumentos e embalagens de vestuário cirúrgico, a fim de estabelecer o potencial para o posterior sem causar qualquer efeito sobre a validade da carga por ciclo. As medidas foram descritas separadamente, antes do primeiro processo de esterilização, durante a descarga e a fase de entrada da água que foi utilizada para o referido processo. Para o desenvolvimento do processo, foram colhidas três amostras com água de osmose e 5 correspondentes à água diretamente da torneira; Após cada amostragem, foram considerados os parâmetros de esterilização, as resoluções ambientais e microbiológicas. Os resultados obtidos mostraram diferenças significativas nos pontos de amostragem que levaram à conclusão de alterações na água de osmose nos diferentes pontos de amostra (entrada, revestimento e descarga) da autoclave em relação às características físico-químicas da água obtida das amostras. pontos da autoclave. Além disso, observou-se a presença de coliformes totais e fecais, mesófilos aeróbicos que indicaram que a água não é adequada para a recirculação dentro da autoclave
Disciplines: Medicina
Keyword: Microbiología,
Agua,
Esterilización,
Análisis microbiológico,
Propiedades fisicoquímicas,
Calidad microbiológica
Keyword: Microbiology,
Water,
Sterilization,
Microbiological analysis,
Physicochemical properties,
Microbiological quality