Automatic electronic device used for the evaluation of cyclic-fatigue resistance of nickel-titanium instruments



Document title: Automatic electronic device used for the evaluation of cyclic-fatigue resistance of nickel-titanium instruments
Journal: Odovtos
Database: PERIÓDICA
System number: 000421043
ISSN: 2215-3411
Authors: 1
2
2
2
2
Institutions: 1Universidad Autónoma de Zacatecas, Area de Ciencias de la Salud, Zacatecas. México
2Universidad Autónoma de San Luis Potosí, Facultad de Estomatología, San Luis Potosí. México
Year:
Season: Ene-Abr
Volumen: 19
Number: 1
Pages: 51-58
Country: Costa Rica
Language: Inglés
Document type: Artículo
Approach: Aplicado, analítico
Spanish abstract El objetivo del presente estudio fue evaluar la fractura a la fatiga cíclica de diferentes instrumentos rotatorios de Niquel-Titanio (sistemas ProTaper® Universal, ProFile® y Mtwo®) en conductos artificiales por medio de un Dispositivo Electrónico Automático (DEA). Se usaron instrumentos de Niquel-Titanio 25/0.06, los cuales se evaluaron en conductos con una curvatura de 45 grados y 2 milímetros de radio. Se analizaron dos parámetros: Fractura a la fatiga cíclica y tiempo a la fractura; además se evaluó la longitud del fragmento separado. Medianas y rangos fueron calculados para cada uno de los grupos. Los resultados fueron analizados por las pruebas de Kruskall–Wallis y U de Mann–Whitney para determinar diferencias estadísticas. El Sistema ProFile mostró una mayor resistencia y tiempo a la fractura en comparación con los sistemas ProTaper y Mtwo (p <0.05). El equipo propuesto en este estudio (DEA) demostró eficiencia para el registro de la información, tiempos de trabajo y duración, número de ciclos, tiempo a la fractura, cambios en la presión y principalmente control del factor humano
English abstract The aim of this study was to evaluate the cyclic-fatigue fracture of different Nickel-Titanium motor-driven rotary instruments (ProTaper® Universal, ProFile®, and Mtwo® systems) in artificial canals by means of an Automatic Electronic Device (AED). The study was performed using Nickel-Titanium instruments 25/0.06 evaluated in canals with a 45-degree curvature and 2-mm radius. The analyses evaluated two parameters: fracture by cyclic fatigue, and time of fracture; in addition, the length of separated fragment was evaluated. Medians and range values were calculated for each group. Data were analyzed by the Kruskall–Wallis and Mann–Whitney U tests to determine statistical difference. The ProFile motor-driven rotator system exhibited highest resistance to fracture due to cyclic fatigue and highest fracture time compared with the ProTaper and Mtwo systems (p <0.05). The equipment proposed in this study (AED) demonstrated efficiency for recording information, automation, scheduled work times and durations, cycle number, time of fracture, pressure changes and, principally control of the human factor
Disciplines: Medicina,
Ingeniería
Keyword: Odontología,
Ingeniería de instrumentos,
Instrumentos níquel-titanio,
Equipos electrónicos,
Instrumentos rotatorios,
Instrumental odontológico,
Fatiga
Keyword: Dentistry,
Instrumentation engineering,
Nickel-titanium instruments,
Electronic devices,
Rotary instruments,
Odontological instruments,
Fatigue
Full text: Texto completo (Ver HTML)