Implementation of real time autocorrelation method employing the DS87C550 microcontroller



Document title: Implementation of real time autocorrelation method employing the DS87C550 microcontroller
Journal: Journal of applied research and technology
Database: PERIÓDICA
System number: 000238811
ISSN: 1665-6423
Authors: 1



Institutions: 1Instituto de Cibernética, Matemática y Física, La Habana. Cuba
Year:
Season: Abr
Volumen: 3
Number: 1
Pages: 73-85
Country: México
Language: Inglés
Document type: Artículo
Approach: Aplicado
Spanish abstract En este trabajo se expone la implementación del método de la Autocorrelación en Tiempo Real de Takeuchi y Hogaki, empleando el microcontrolador DS87C550 de amplias prestaciones, con el objetivo de obtener el valor de la frecuencia de los latidos cardíacos fetales y mostrarlos en un visualizador LCD, a partir de la señal Doppler proveniente de un Detector Fetal. Se simuló el algoritmo de autocorrelación en una PC para conocer su comportamiento dinámico, a partir de diferentes señales de entrada, obteniéndose finalmente un criterio para llevar a cabo el reconocimiento y la selección de la primera cresta conformada, mediante la cual se determina el valor del período de la señal procesada. Consecuentemente, se creó un algoritmo original optimizado, implementado en el microcontrolador, mediante el cual se obtiene el valor de la frecuencia cardíaco fetal en pulsos por minuto (ppm). Cada 1,2 seg., como resultado de la promediación de dos valores de frecuencia calculados durante ese intervalo de tiempo
English abstract In this work, the implementation of Real Time Autocorrelation method proposed by Takeuchi and Hogaki, is exposed. The purpose is to obtain the frequency of the fetal cardiac beats, originated from a Fetal Detector, using a wide-benefits DS87C550 microcontroller. The value of frequency is showed in a LCD. The autocorrelation algorithm was simulated in a PC to know its dynamic behavior from selected signals. A criterion to carry out the recognition and the selection of the first conformed crest, was obtained. By means of this criterion, the period of the processed signal is determined. Consequently, an optimized and original algorithm was created and implemented in the microcontroller, where the value of the fetal cardiac frequency (given in pulses per minute, ppm.) is obtained each 1.2 sec. In that time, two calculated values of frequency are averaged
Disciplines: Ingeniería
Keyword: Ingeniería de control,
Ingeniería electrónica,
Tiempo real,
Autocorrelación,
Doppler,
Ultrasonido
Keyword: Engineering,
Control engineering,
Electronic engineering,
Real time,
Autocorrelation,
Ultrasound,
Doppler