Spanish abstract La ablación por radiofrecuencia es una técnica eficaz y segura para el tratamiento de diferentes tipos de arritmias. La ablación por radiofrecuencia se realiza mediante fluoroscopia, una guía de navegación estándar, que está asociada con la exposición a la radiación y sus efectos nocivos bien reconocidos para los pacientes y para el personal de laboratorio. En la última década, los sistemas de mapeo electroanatómico han experimentado un fuerte desarrollo. A pesar de sus indiscutibles ventajas, no incluyen información obtenida por fluoroscopia en tiempo real. El módulo CARTO-UNIVU™ aborda esta importante limitación, ya que combina imágenes de fluoroscopia con el mapeo eletroanatómico tridimensional (3D) en una sola vista 3D, lo que permite una reducción pronunciada de la exposición a la radiación. Presentamos cuatro casos de nuestra primera experiencia en un solo centro con el nuevo módulo CARTO-UNIVU™
English abstract Radiofrequency ablation is an effective and safe technique for the treatment of different types of arrhythmias. Radiofrequency ablation is performed using fluoroscopy, a standard navigation guide, which is related to radiation exposure and its well-known harmful effects on patients and laboratory staff. In the last decade, electroanatomic mapping systems have noted a steep development. Despite their indisputable advantages, they do not include information obtained by real-time fluoroscopy. This important limitation is tackled by the new CARTO-UNIVU™ module as it seamlessly combines fluoroscopy images with three-dimensional (3D) electroanatomic mapping into a single accurate 3D view, enabling a pronounced reduction in radiation exposure. We report four cases of our single center first experience of the new CARTO-UNIVU™ module
Disciplines: Medicina
Keyword: Salud ocupacional,
Radiología,
Exposición ocupacional,
Fluoroscopia,
Radiación,
Ablación por radiofrecuencia,
Mapeo electroanatómico
Keyword: Occupational health,
Radiology,
Occupational exposure,
Fluoroscopy,
Radiation,
Radiofrequency ablation,
Electroanatomic mapping
Full text: Texto completo (Ver HTML) Texto completo (Ver PDF)