Effect of acetonitrile concentration on acylcarnitines measurement by tandem mass spectrometry



Document title: Effect of acetonitrile concentration on acylcarnitines measurement by tandem mass spectrometry
Journal: Biosalud (Manizales)
Database: PERIÓDICA
System number: 000363871
ISSN: 1657-9550
Authors: 1
Institutions: 1Universidad de Caldas, Departamento de Ciencias Básicas de la Salud, Manizales, Caldas. Colombia
Year:
Season: Ene-Jun
Volumen: 9
Number: 1
Country: Colombia
Language: Inglés
Document type: Artículo
Approach: Aplicado, analítico
Spanish abstract Las diferentes etapas que conforman el análisis de acilcarnitinas por espectrometría de masas en tándem, tales como extracción, derivatización, inyección y otras, pueden ser influenciadas por algunos factores técnicos incrementando o disminuyendo los niveles de detección. Objetivo: el presente estudio evaluó el efecto de la concentración del acetonitrilo utilizado durante la determinación de acilcarnitinas en sangre, sobre la sensibilidad obtenida durante el análisis. Metodología: antes del análisis de acilcarnitinas por espectrometría de masas en tándem, las muestras fueron disueltas en diferentes disoluciones de acetonitrilo en agua [50, 60, 70, 80, 90, and 100% (v/v)] y cada espécimen de sangre fue procesado 5 veces para cada dilución. Resultados: se observó que a medida que se incrementan los niveles de acetonitrilo, la intensidad de los picos de acilcarnitinas se incrementan significativamente. Sin embargo, a las concentraciones más altas de acetonitrilo, éste reacciona con el poliestireno de las bandejas, apareciendo picos en el perfil de acilcarnitinas, específicamente a m/z 302. Conclusión: una mezcla al 70% v/v acetonitrilo/agua, se recomienda para usar como solvente óptimo, para la disolución de los extractos antes del análisis de acilcarnitinas en sangre mediante espectrometría de masas en tándem
English abstract The several steps for acylcarnitine analysis by tandem mass spectrometry such as extraction, derivatisation, injection and others, can be influenced by some technical factors improving or impairing the levels of detection. Objective: the present study evaluated the effect of different concentrations of the acetonitrile used during blood acylcarnitines measurement on the sensitivity obtained during the analysis. Methodology: prior to acylcarnitine analysis by tandem mass spectrometry, samples were re-dissolved in different acetonitrile in water dilutions [50, 60, 70, 80, 90, and 100% (v/v)] and each single blood specimen was processed five times for each dilution. Results: it was observed that by increasing the concentration of acetonitrile the intensity of acylcarnitine peaks significantly increased. However at the highest concentrations of acetonitrile, this reacted with the polystyrene material of the microtitre plates, and resulted in peaks appearing in acylcarnitine profiles, specifically at m/z 302. Conclusion: a mixture of 70% v/v acetonitrile/water is recommended to use as optimum solvent to dissolve the extracts prior to blood acylcarnitine analysis by tandem mass spectrometry
Disciplines: Medicina
Keyword: Diagnóstico,
Bioquímica,
Carnitina,
Acilcarnitina,
Espectrometría de masas,
Medición,
Sangre
Keyword: Medicine,
Diagnosis,
Biochemistry,
Carnitine,
Acylcarnitine,
Mass spectrometry,
Measurement,
Blood
Full text: Texto completo (Ver HTML)