Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging



Título del documento: Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging
Revue: Revista mexicana de física
Base de datos: PERIÓDICA
Número de sistema: 000348072
ISSN: 0035-001X
Autores: 1
1
2
2
Instituciones: 1Robarts Research Institute, Imaging Research Laboratories, London, Ontario. Canadá
2Universidad Autónoma Metropolitana, Centro de Investigación en Instrumentación e Imagenología Médica, Iztapalapa, Distrito Federal. México
Año:
Periodo: Abr
Volumen: 55
Número: 2
Paginación: 140-144
País: México
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Aplicado, descriptivo
Resumen en español Una antena del tipo solenoide fue construida para generar imagenes por resonancia magnetica de ratones con un sistema de cuerpo entero de 3 T de uso clınico y un arreglo de antenas de gradientes insertable. El prototipo de antena consistio en 5 vueltas con una longitud total de 4 cm y un diametro de 2.5 cm. El desempeno de la antena se midio usando el factor Q para los casos cargado y sin carga cuyos resultados fueron 161.78 y 178.03 respectivamente. Estos valores concuerdan muy bien con los reportados en la literatura. Se obtuvieron imagenes de un maniquı construido especıficamente para este prop´osito con isletas marcadas con un agente de contraste, usando una secuencia gradiente eco. La interaccion electromagnetica entre el conjunto de gradientes insertables y la antena solenoide es pobre, y no hay evidencia de artefactos de imagen en las imagenes de cuerpo entero del raton. Esta experiencia preliminar muestra que esta clase de antena ofrece una alta calidad de imagenes de raton que es posible obtener con un sistema de 3 T. Las antenas de volumen son una buena eleccion para obtener imagenes de alta resolucion espacial en investigacion preclınica de ratones a campos magneticos altos
Resumen en inglés A solenoid coil was built for magnetic resonance imaging of the mice. A coil prototype composed of 5 turns, with a length of 4 cm and 2.5 cm radius was developed to acquire (whole) body mouse magnetic resonance images at 130 MHz and an insertable gradient coil set. Coil performance was measured using the Q factor for both the loaded and unloaded cases were 161.67 and 178.03, respectively. These Q factors compare very well with those values reported in the literature. The images were acquired with a clinical 3 T system equipped with a custom-built gradient insert coil and gradient echo image sequence. Both phantom and in vivo images showed good signal-to-noise ratio and uniformity. The electromagnetic interaction between the insertable coils and the solenoidal coil is poor, and no image artefacts are present in the whole-body image of the mouse. This preliminary experience has shown that consistent high quality MR images of the mice can be obtained using this particular hardware configuration, making it a promising method for acquisition of high-spatial resolution MR images of mice. Volume coils are still a good choice when combined with high field MR imagers and standard gradient echo sequences for the magnetic resonance imaging of the mouse
Disciplinas: Física y astronomía,
Ciencia y tecnología
Palabras clave: Física atómica y molecular,
Tecnología,
Imágenes,
Antena solenoide,
Simulación electromagnética,
Resonancia magnética,
Ratones
Keyword: Physics and astronomy,
Science and technology,
Atomic and molecular physics,
Technology,
Images,
Solenoid coil,
Electromagnetic simulation,
Magnetic resonance,
Mice
Texte intégral: Texto completo (Ver PDF)