Intercalibration of the San Pedro Mártir and CTIO DIMM units



Título del documento: Intercalibration of the San Pedro Mártir and CTIO DIMM units
Revue: Revista mexicana de astronomía y astrofísica
Base de datos: PERIÓDICA
Número de sistema: 000349197
ISSN: 0185-1101
Autores: 1
1
1
1
1
1
1
Instituciones: 1Universidad Nacional Autónoma de México, Instituto de Astronomía, Ensenada, Baja California. México
Año:
Periodo: Oct
Volumen: 43
Número: 2
Paginación: 283-290
País: México
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Analítico, teórico
Resumen en español Comparamos mediciones simultaneas de seeing obtenidas durante 14 noches con los monitores de movimiento diferencial de imagen (DIMM) usados en el Observatorio Astron omico Nacional en San Pedro M artir (SPD) y en Cerro Tololo Inter- American Observatory (RoD). Para el conjunto de datos, compuesto de 1581 mediciones cuasi-simult aneas, encontramos que la media y la mediana de las diferencias de seeing RoD-SPD son +0.004 0.13800 y +0.01000, respectivamente. Tambi en descubrimos que la mediana de las diferencias de seeing RoD-SPD es +0.04100 cuando el seeing es inferior a 100; 􀀀0:03200 cuando est a entre 100, y 1.500 y 􀀀0:29200 cuando es superior a 1.500. Dado que el seeing es usualmente menor que 100, concluimos que las mediciones hechas con unidades tipo SPD deben incrementarse entre 0.0100 y 0.0400 al ser comparadas con unidades tipo RoD. Esta correcci on es mucho menor que la dispersi on natural de medidas de seeing que ocurren a lo largo de cualquier noche, y tiene sentido hacerla s olo si las condiciones operativas en ambos sitios son pr acticamente las mismas
Resumen en inglés We compare simultaneous seeing measurements produced by the di erential image motion monitor (DIMM) units used at the Observatorio Astron omico Nacional at San Pedro M artir (SPD) and at Cerro Tololo Inter-American Observatory (RoD), for a total of 14 nights. For the data set, made of 1581 nearly-synchronous measurements, we nd that the mean and median RoD-SPD seeing di erences are +0.004 0.13800 and +0.01000 respectively. We also nd that the median of the RoDSPD seeing measurements is +0.04100 when seeing is less than 100, 􀀀0:03200 when it is between 100 and 1.500, and 􀀀0:29200 when it is larger than 1.500. Since seeing is usually smaller than 100, we conclude that measurements obtained with SPD-like units should be increased by 0.0100 to 0.0400 when comparisons are made with sites using RoD-like units. This correction is much smaller than the natural dispersion of seeing measurements along any night, and it makes sense only when operational conditions in both sites are practically the same
Disciplinas: Física y astronomía,
Ingeniería
Palabras clave: Astronomía,
Optica,
Ingeniería de instrumentos,
Calibración,
Pruebas de sitio,
Seeing,
Observatorio Astronómico Nacional,
San Pedro Mártir,
Baja California,
México
Keyword: Physics and astronomy,
Engineering,
Astronomy,
Optics,
Instrumentation engineering,
Calibration,
Site testing,
Seeing,
Observatorio Astronomico Nacional,
San Pedro Martir,
Baja California,
Mexico
Texte intégral: Texto completo (Ver PDF)