Territory Management Based On The Assessment Of Environmental Noise In Near Areas To Two Medical Centers Of Zone Planning Units 44 And 47 In Bogotá



Título del documento: Territory Management Based On The Assessment Of Environmental Noise In Near Areas To Two Medical Centers Of Zone Planning Units 44 And 47 In Bogotá
Revue: Revista ingeniería solidaria
Base de datos: PERIÓDICA
Número de sistema: 000432968
ISSN: 2357-6014
Autores: 1
1
1
Instituciones: 1Universidad Libre, Facultad de Ingeniería, Bogotá. Colombia
Año:
Periodo: Ene
Volumen: 16
Número: 1
País: Colombia
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Aplicado, descriptivo
Resumen en español La localidad de Kennedy ha presentado altos niveles de ruido ambiental, lo cual es preocupante debido a sus efectos sobre la salud de las personas.Objetivo: Esta investigación se realizó con el propósito de; recopilar información actualizada sobre el ruido ambiental en la localidad de Kennedy, evaluar el cumplimiento normativo e identificar los fenómenos para establecer acciones que conduzcan a su mitigación.Metodología: El proceso de medición se guio bajo las pautas de ISO 1996: 1 y los parámetros establecidos en la Res. 627/2006 del ministerio de ambiente.Resultados: Los niveles de ruido ambiental exceden los límites máximos permisibles (55 dB) en los diferentes días y horas de medición, también se determinó su relación principal con el alto flujo vehicular, así como con actividades comerciales formales e informales alrededor de los centros médicos. .Conclusión: No existe cumplimiento normativo en relación con el ruido ambiental y el plan territorial establecido en la UPZ. Las acciones sugeridas son; uso de parques para plantar árboles nativos que actúan como barreras biológicas, no uso de las calles circundantes como caminos secundarios de tráfico y reorganización de las actividades comerciales.Originalidad: Se obtuvieron datos actualizados de ruido ambiental y se identificaron problemas de crecimiento y desarrollo inapropiados. Limitaciones:Falta de información de mediciones de ruido ambiental en otros sectores de la localidad
Resumen en inglés The Kennedy town has presented high levels of environmental noise, which is a worrying aspect due to its correlation with the effects on people’s health.Objective:This research was conducted for the purpose of compiling updated information on environmental noise in the Kennedy locality and evaluating regulatory compliance and identifing the phenomena to establish actions that lead to its mitigation.Methodology:The measurement process was guided under the guidelines of ISO 1996:1 and the parameters established in Res. 627/2006 of the Ministry of Environment.Results:The ambient noise levels exceed the maximum permissible limits (55 dB) on the different days and hours of measurement. It was also determined that this phenomenon is mainly related to high vehicular flow as well as formal and informal commercial activities around medical centers.Conclusion:There is no regulatory compliance in relation to environmental noise and the territorial plan esta-blished in the UPZ. The suggested actions are: use of parks to plant native trees that act as biological barriers, non-use of surrounding streets as secondary traffic roads and reorganization of trade activities.Originality:Updated environmental noise data was obtained around medical centers in Kennedy and problems of inappropriate growth and development were identified.Limitations:Lack of information on environmental noise measurements in other sectors of the area
Resumen en portugués A cidade de Kennedy apresentou altos níveis de ruído ambiente, o que é preocupante devido aos seus efeitos na saúde das pessoas.Objetivo: Esta investigação foi realizada com o objetivo de; reunir informações atualizadas sobre o ruído am-biental na cidade de Kennedy, avaliar a conformidade regulatória e identificar fenômenos para estabelecer ações que levem à sua mitigação.Metodologia: O processo de medição foi orientado pelas diretrizes da ISO 1996: 1 e pelos parâmetros estabe-lecidos na Res. 627/2006 do Ministério do Meio Ambiente.Resultados: os níveis de ruído ambiente excedem os limites máximos permitidos (55 dB) nos diferentes dias e horas de medição, também foi determinada sua principal relação com o alto fluxo veicular, bem como com atividades comerciais formais e informais nos centros médicos . .Conclusão: Não há conformidade regulamentar com relação ao ruído ambiental e ao plano territorial esta-belecido na UPZ. As ações sugeridas são; uso de parques para plantar árvores nativas que atuam como ba-rreiras biológicas, não uso de ruas vizinhas como vias secundárias de tráfego e reorganização de atividades comerciais.Originalidade: Foram obtidos dados atualizados de ruído ambiental e identificados problemas inadequados de crescimento e desenvolvimento.Limitações: Falta de informação sobre medições de ruído ambiental em outros setores da localidade
Disciplinas: Ingeniería
Palabras clave: Ingeniería ambiental,
Urbanismo,
Planeación urbana,
Contaminación por ruido
Keyword: Environmental engineering,
Urbanism,
Urban planning,
Noise pollution
Texte intégral: https://revistas.ucc.edu.co/index.php/in/article/view/3083/2810