Revista: | Revista ingeniería de construcción |
Base de datos: | PERIÓDICA |
Número de sistema: | 000388835 |
ISSN: | 0718-915X |
Autores: | Zellat, Kaoutar1 Kadri, Tahar1 |
Instituciones: | 1University of Abdelhamid Ibn Badis Mostaganem, Department of Civil Engineering, Mostaganem. Argelia |
Año: | 2015 |
Periodo: | Dic |
Volumen: | 30 |
Número: | 3 |
Paginación: | 210-214 |
País: | Chile |
Idioma: | Español |
Tipo de documento: | Artículo |
Enfoque: | Aplicado, descriptivo |
Resumen en español | El objetivo de un sistema de aislación sísmica es proporcionar medios adicionales de disipación de la energía, reduciendo así la aceleración transmitida hacia una superestructura. Con la finalidad de demostrar la efectividad de la aislación sísmica y comprender el comportamiento de los puentes con aislación sísmica, se consideró un puente de tablero continuo de tres tramos construidos en hormigón armado. Se modeló el puente como un modelo discreto y los desplazamientos relativos del aislador sísmico son cruciales desde el punto de vista del sistema de aislación y juntas de separación a nivel del estribo. Aquí, se presentan los sistemas de control pasivo incluyendo los resultados de algunos importantes ensayos experimentales |
Resumen en inglés | The purpose of an isolation system is to provide an additional means of energy dissipation, thereby reducing the transmitted acceleration into the superstructure. In order to demonstrate the effectiveness of seismic isolation and understand the behavior of seismically isolated bridges a three-span continuous deck bridge made of reinforced concrete is considered. The bridge is modeled as a discrete model and the relative displacements of the isolation bearing are crucial from the design point of view of isolation system and separation joints at the abutment level. The systems presented here are passive control systems and the results of some important experimental tests are also included. The results show that the base shear in the piers is significantly reduced for the isolated system as compared to the non isolated system in the both directions of the bridge. This indicates that the isolation systems are effective in reducing the earthquake response of the bridge |
Disciplinas: | Ingeniería |
Palabras clave: | Ingeniería civil, Puentes, Aislamiento sísmico, Disipación de energía, Construcciones antisísmicas |
Keyword: | Engineering, Civil engineering, Bridges, Seismic isolation, Energy dissipation, Antiseismic constructions |
Texto completo: | Texto completo (Ver PDF) |