Evaluación in vitro de la rugosidad superficial y la alteración de color de dos tipos de ionómeros de vidrio, luego de ser sometidos a diferentes bebidas



Título del documento: Evaluación in vitro de la rugosidad superficial y la alteración de color de dos tipos de ionómeros de vidrio, luego de ser sometidos a diferentes bebidas
Revue: Revista de odontopediatría latinoamericana
Base de datos: PERIÓDICA
Número de sistema: 000413296
ISSN: 2174-0798
Autores:
1
2
2
Instituciones: 1Universidad Nacional de Concepción, Facultad de Odontología, Concepción. Paraguay
2Universidade de Sao Paulo, Faculdade de Odontologia de Ribeirao Preto, Ribeirao Preto, Sao Paulo. Brasil
Año:
Periodo: Jul-Dic
Volumen: 7
Número: 2
País: Colombia
Idioma: Español
Tipo de documento: Artículo
Enfoque: Analítico, descriptivo
Resumen en español El objetivo de este estudio in vitro fue analizar la rugosidad superficial y la alteración de color de dos tipos de ionómeros vítreos luego de ser sometidos a diferentes soluciones. En una matriz de teflón (8x2mm), fueron confeccionados 60 cuerpos de prueba con 2 tipos de ionómeros fotopolimerizables: 30 para el Fuji II LC (M1) y otros 30 para el Ketac N100 (M2). El aparato utilizado fue el Elipar Freelight 2 3M Espe. La fotopolimerización se realizó por 20 segundos cada cuerpo de prueba. Luego de la confección, los sesenta cuerpos de prueba fueron mantenidos en gasa humedecida por 24 hs en estufa a 37ºC y luego se clasificaron y luego se dividieron en tres grupos de 10 cada uno para ser sometidos a 3 tipos diferentes de soluciones: agua destilada (S1), bebida carbonatada (S2) y jugo cítrico (S3) por 90 segundos diariamente durante 14 días. Las lecturas de la alteración de color, obtenidas a través de un colorímetro, y las de rugosidad superficial, realizadas por medio del rugosímetro, fueron realizadas a las 48 hs. (T0) y luego a los 14 días (T1). Los resultados obtenidos fueron sometidos al test ANOVA y Tukey (p≤0.05). Los resultados mostraron que; a) La bebida carbonatada (S2) tuvo mayor media de alteración de color (ΔE*) en relación a las otras soluciones, b) que Ketac N100 (M2) tuvo mayor media con respecto a la rugosidad superficial en la interacción material por solución. Por tanto, se concluyó que trascurrido determinado período de tiempo las propiedades estéticas y físico-mecánicas de los materiales estudiados se ven afectados
Resumen en inglés The aim of this in vitro study was to examine the surface roughness and discoloration of two types of glass ionomer had been subjected to different solutions. In a matrix of Teflon (8x2mm), 60 test bodies were prepared with 2 types of resin modified glass ionomers: 30 for Fuji II LC® (M1) and the other 30 for Ketac N100® (M2). The apparatus was Freelight two 3M ESPE Elipar. Photopolymerization was carried out for 20 second each test body. After the preparation, the seventy-two specimens were kept in gauze soaked for 24 hours in an oven at 37°C and then were sorted and divided into three groups of 12 each to be subjected, for 90 seconds each day at 3 different types of solutions: distilled water (S1), carbonated beverage (S2) and citrus juice (S3) for 14 days. Readings from discoloration, obtained through a colorimeter, and the surface roughness made using the profilometer were performed after 48 hours (T0) and after day 14 (T1). The results were submitted to ANOVA and Tukey test (p ≤ 0.05). The results showed that: a) The carbonated beverage (S2) had higher mean discoloration (ΔE *) compared to the other solutions, b) Ketac N100®(M2) had higher mean with respect to the interaction surface roughness material solution. Therefore, it was concluded that certain period of time elapsed aesthetic properties and physico-mechanical properties of the material studied are affected
Resumen en portugués O objetivo deste estudo in vitro foi analisar a rugosidade superficial e a alteraçã o de cor de dois tipos de ionômeros de vidrio após serem submetidos a diferentes bebidas. Em uma matriz de te ón (8x2mm), foram confeccionados 60 corpos de prova com 2 tipos de ionômeros fotopolimerizáveis: 30 para o Fuji II LC (M1) e outros 30 para o Ketac N100 (M2). O aparelho utilizado foi o Elipar Freelight 2 3M Espe. A fotopolimerização foi realizada por 20 segundos em cada corpo de prova. Após a confecçã o, os 60 corpos de prova foram mantidos em gaze umedecida por 24 hrs em estufa a 37o C e divididos em 3 grupos de 10 cada um, para ser submetidos a 3 tipos diferentes de soluçõ es: água destilada (S1), bebida carbonatada (S2) e suco cítrico (S3) por 90 segundos diariamente durante 14 dias. As leituras de alteraçã o de cor, obtidas através de um colorímetro, e das de rugosidades superficial, realizadas por meio do rugosímetro, foram realizadas após 48 hs. (T0) e após 14 dias (T1). Os resultados obtidos foram submetidos à test ANOVA e Tukey (p≤0.05). Os resultados mostraram que; a) a bebida carbonatada (S2) teve maior media de alteraçã o de cor (ΔE*) em relaçã o às outras soluçõ es, b) que Ketac N100 (M2) teve maior media com respeito a rugosidade superficial na interaçã o material pela soluçã o. Podemos concluir que a partir de determinado período de tempo as propriedades estéticas e físico-mecânicas dos materiais estudados são afetadas
Disciplinas: Medicina
Palabras clave: Odontología,
Materiales dentales,
Ionómeros de vidrio,
Rugosidad superficial,
Alteración del color,
Bebidas carbonatadas,
Jugo de frutas
Keyword: Medicine,
Dentistry,
Dental materials,
Glass ionomers,
Surface roughness,
Color stability,
Carbonated beverages,
Fruits juices
Texte intégral: Texto completo (Ver HTML)