Determination of Trace Amount of Lead in Industrial and Municipal Effluent Water Samples Based on Dispersive Liquid-Liquid Extraction



Título del documento: Determination of Trace Amount of Lead in Industrial and Municipal Effluent Water Samples Based on Dispersive Liquid-Liquid Extraction
Revue: Journal of the Mexican Chemical Society
Base de datos: PERIÓDICA
Número de sistema: 000377230
ISSN: 1665-9686
Autores: 1
2
2
Instituciones: 1Iranian Petroleum Industry Health Research Institute, Occupational and Environmental Health Research Center, Teherán. Irán
2Semnan University, College of Science, Semnan. Irán
Año:
Periodo: Abr-Jun
Volumen: 58
Número: 2
Paginación: 137-141
País: México
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Experimental, aplicado
Resumen en español En este estudio se desarrolló un método simple, sensible y exacto para la determinación del ion plomo, combinando la extracción dispersiva líquido-líquido iónico (IL-DLLE) y la espectrometría de absorción atómica de flama. Se utilizaron disulfuro de tetraetiltiuram (TETD), acetona y 1-octil-3-metilimidazolium hexafluorofosfato como agente quelante, disolvente de dispersión y disolvente de extracción, respectivamente. Bajo las condiciones óptimas, la gráfica de calibración fue lineal en el intervalo de 5-190 μg L-1 de plomo y el límite de detección fue de 0.8 μg L-1 para un volumen de muestra de 200 mL. El método propuesto fue validado mediante el análisis de un material de referencia certificado y aplicado exitosamente para la determinación de plomo en muestras reales de agua
Resumen en inglés In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (IL-DLLE) with flame atomic absorption spectrometry. Tetraethylthiuram disulfide (TETD), acetone and 1-octyl-3-methylimidazolium hexafluorophosphate [(C8MIM) (PF6)] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L-1 of lead and the detection limit was 0.8 μg L-1 with a sample volume of 200 mL. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples
Disciplinas: Química
Palabras clave: Química analítica,
Salud pública,
Análisis de agua,
Plomo,
Extracción líquido-líquido,
Disulfuro de tetraetiltiuram,
Espectroscopía de absorción atómica
Keyword: Chemistry,
Analytical chemistry,
Public health,
Water analysis,
Lead,
Liquid-liquid extraction,
Tetraethylthiuram disulfide,
Atomic absorption spectrometry
Texte intégral: Texto completo (Ver HTML)