Improved UV-Vis detection of lanthanides in synthetic standards by capillary electrophoresis: A new experimental evidence of the actual systematic odd-even pattern in sensitivities and detection limits



Título del documento: Improved UV-Vis detection of lanthanides in synthetic standards by capillary electrophoresis: A new experimental evidence of the actual systematic odd-even pattern in sensitivities and detection limits
Revue: Actas INAGEQ
Base de datos: PERIÓDICA
Número de sistema: 000329120
Autores: 1
1
Instituciones: 1Universidad Nacional Autónoma de México, Centro de Investigación en Energía, Temixco, Morelos. México
Año:
Periodo: Sep
Volumen: 12
Número: 1
Paginación: 27-28
País: México
Idioma: Inglés
Tipo de documento: Conferencia o discurso
Enfoque: Experimental
Resumen en español The systematic odd-even pattern of sensitivities and detection limits (LODs) of lanthanides, previously observed, in mass spectrometric and chromatographic measurements[1-5] was experimentally investigated. Well-designed geochemometric experiments of capillary electrophoresis (CE) for determination of lanthanides in synthetic standards with equal amounts of lanthanides were carried out. An improved UV-Vis detection system based on indirect measurement at a wavelength of 214 nm, a voltage of +25 kV and a hydrostatic injection (100 mm for 20 s) were successfully used. A conventional fused-silica capillary (355 x 0.075 mm) was employed for all the lanthanide separations. Complete separation for all the lanthanides was efficiently achieved in ~2.8 min at a capillary temperature of 15ºC. The efficient separations show excellent resolutions (R) ranging from 1.324 to 5.741 and capillary efficiency values (N) in the interval 37289 to 939127. The background electrolyte used consisted of 0.010 M UVCat-1 (Waters) with 0.004 M HIBA at a pH 4.4. A good reproducibility in migration times (< 2.7 %RSD), peak areas (< 3.8 %RSD) and peak heights (2.7 %RSD) were consistently found. Two types of calibration curves were derived from experimental CE data based on both peak area and peak height measurements versus lanthanide amount data, respectively. All calibration curves were based on seven replicates to transport the uncertainties of the measurements, and were prepared using the weighted linear regression (WLR) model. The statistical parameters of the WLR were used for estimating individual sensitivities and LODs for all lanthanides. The calculated sensitivities were greater for lanthanides with an odd-atomic number (i.e., 57La, 59Pr, 63Eu, 65Tb, 67Ho, 69Tm, and 71Lu) than for their corresponding neighboring element with an even-atomic number (i.e., 58Ce, 60Nd, 62Sm, 64Gd, 66Dy, 68Er, and 70Yb)
Disciplinas: Geociencias,
Química
Palabras clave: Geofísica,
Química analítica,
Lantánidos,
Geoquímica,
Espectrometría de masas,
Limites de detección
Keyword: Earth sciences,
Chemistry,
Geophysics,
Analytical chemistry,
Lanthanides,
Geochemistry,
Mass spectrometry,
Detection limits
Solicitud del documento
Nota: El envío del documento tiene costo.









Los documentos originales pueden ser consultados en el Departamento de Información y Servicios Documentales, ubicado en el Anexo de la Dirección General de Bibliotecas (DGB), circuito de la Investigación Científica a un costado del Auditorio Nabor Carrillo, zona de Institutos entre Física y Astronomía. Ciudad Universitaria UNAM. Ver mapa
Mayores informes: Departamento de Información y Servicios Documentales, Tels. (5255) 5622-3960, 5622-3964, e-mail: sinfo@dgb.unam.mx, Horario: Lunes a viernes (8 a 16 hrs.)