Journal: | Revista mexicana de ingeniería biomédica |
Database: | PERIÓDICA |
System number: | 000407537 |
ISSN: | 0188-9532 |
Authors: | Ireta Moreno, F1 Martínez Celorio, R.A1 González Rolón, B1 Morales Sánchez, E2 Castro Sánchez, R1 Hernández Fusilier, D1 González Peña, R3 Salvador Palmer, R3 |
Institutions: | 1Universidad de Guanajuato, Dirección de Ingeniería, Salamanca, Guanajuato. México 2Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Querétaro. México 3Universidad de Valencia, Grupo de Biofísica, Valencia. España |
Year: | 2010 |
Season: | Jul |
Volumen: | 31 |
Number: | 1 |
Pages: | 73-79 |
Country: | México |
Language: | Español |
Document type: | Artículo |
Approach: | Experimental, aplicado |
Spanish abstract | En este trabajo se propone un método para determinar la descalcificación ósea mediante el Factor de Disipación Dieléctrica (FDD). El estudio se realizó sobre un conjunto de ocho muestras preparadas en forma de pastilla a partir de hueso de cerdo. Las pastillas fueron preparadas siguiendo un protocolo para inducir de forma controlada un grado de descalcificación. Éstas se probaron en una celda de prueba tipo capacitiva, la cual se conectó a un analizador de impedancia eléctrica que permite medir el FDD en función de la frecuencia. Los resultados obtenidos en el intervalo de frecuencia de 70 MHz a 90 MHz sugieren que el método propuesto permite evaluar cuantitativamente la descalcificación ósea. La importancia de este estudio radica en la posibilidad de desarrollar una técnica no invasiva para medir la descalcificación de los huesos y el diseño de equipos que permitan evaluar la osteoporosis, dado que actualmente esta patología se determina mediante técnicas de rayos X con capacidad ionizante |
English abstract | In this paper, it is introduced a method to determine the bone decalcification using the so called dielectric dissipation factor (DDF). This study was developed using a set of eight samples taken from hog bone. These samples were arranged in a tablet shape. These tablets were prepared following a protocol that provokes a controlled decalcification degree. The samples were tested in a capacitive cell that was interconnected with an electric impedance analyzer. This equipment is able to measure the DDF as a function of frequency. The aforementioned tests were run in the interval of 70 MHz to 90 MHz. These results suggest that the proposed technique is a good choice to evaluate the bone decalcification quantitatively. The importance of this study is the possibility of develop a non invasive technique to measure the decalcification degree. Indeed, this method may be used to design a new generation of equipments that can be used to measure the osteoporosis. A non invasive method offers a less dangerous procedure to determine the effect of this illness, especially because the available schemes use ionizing radiation |
Disciplines: | Medicina, Ingeniería |
Keyword: | Diagnóstico, Medicina experimental, Biofísica, Ingeniería biomédica, Osteoporosis, Descalcificación, Tejido óseo, Factor de disipación dieléctrica |
Keyword: | Medicine, Engineering, Diagnosis, Experimental medicine, Biophysics, Biomedical engineering, Osteoporosis, Decalcification, Bone tissue, Dielectric dissipation factor |
Full text: | Texto completo (Ver HTML) |