Estudio de muestras óseas descalcificadas mediante factor de disipación dieléctrica



Document title: Estudio de muestras óseas descalcificadas mediante factor de disipación dieléctrica
Journal: Revista mexicana de ingeniería biomédica
Database: PERIÓDICA
System number: 000407537
ISSN: 0188-9532
Authors: 1
1
1
2
1
1
3
3
Institutions: 1Universidad de Guanajuato, Dirección de Ingeniería, Salamanca, Guanajuato. México
2Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Querétaro. México
3Universidad de Valencia, Grupo de Biofísica, Valencia. España
Year:
Season: Jul
Volumen: 31
Number: 1
Pages: 73-79
Country: México
Language: Español
Document type: Artículo
Approach: Experimental, aplicado
Spanish abstract En este trabajo se propone un método para determinar la descalcificación ósea mediante el Factor de Disipación Dieléctrica (FDD). El estudio se realizó sobre un conjunto de ocho muestras preparadas en forma de pastilla a partir de hueso de cerdo. Las pastillas fueron preparadas siguiendo un protocolo para inducir de forma controlada un grado de descalcificación. Éstas se probaron en una celda de prueba tipo capacitiva, la cual se conectó a un analizador de impedancia eléctrica que permite medir el FDD en función de la frecuencia. Los resultados obtenidos en el intervalo de frecuencia de 70 MHz a 90 MHz sugieren que el método propuesto permite evaluar cuantitativamente la descalcificación ósea. La importancia de este estudio radica en la posibilidad de desarrollar una técnica no invasiva para medir la descalcificación de los huesos y el diseño de equipos que permitan evaluar la osteoporosis, dado que actualmente esta patología se determina mediante técnicas de rayos X con capacidad ionizante
English abstract In this paper, it is introduced a method to determine the bone decalcification using the so called dielectric dissipation factor (DDF). This study was developed using a set of eight samples taken from hog bone. These samples were arranged in a tablet shape. These tablets were prepared following a protocol that provokes a controlled decalcification degree. The samples were tested in a capacitive cell that was interconnected with an electric impedance analyzer. This equipment is able to measure the DDF as a function of frequency. The aforementioned tests were run in the interval of 70 MHz to 90 MHz. These results suggest that the proposed technique is a good choice to evaluate the bone decalcification quantitatively. The importance of this study is the possibility of develop a non invasive technique to measure the decalcification degree. Indeed, this method may be used to design a new generation of equipments that can be used to measure the osteoporosis. A non invasive method offers a less dangerous procedure to determine the effect of this illness, especially because the available schemes use ionizing radiation
Disciplines: Medicina,
Ingeniería
Keyword: Diagnóstico,
Medicina experimental,
Biofísica,
Ingeniería biomédica,
Osteoporosis,
Descalcificación,
Tejido óseo,
Factor de disipación dieléctrica
Keyword: Medicine,
Engineering,
Diagnosis,
Experimental medicine,
Biophysics,
Biomedical engineering,
Osteoporosis,
Decalcification,
Bone tissue,
Dielectric dissipation factor
Full text: Texto completo (Ver HTML)