Assessment of Three Alternating Pressure Sequences Applied to a Dynamic Cushion to Relieve Pressure on Seating Areas



Document title: Assessment of Three Alternating Pressure Sequences Applied to a Dynamic Cushion to Relieve Pressure on Seating Areas
Journal: Revista mexicana de ingeniería biomédica
Database: PERIÓDICA
System number: 000387205
ISSN: 0188-9532
Authors: 1
1
1
2
2
2
2
1
Institutions: 1Instituto Politécnico Nacional, Centro de Investigación y de Estudios Avanzados, México, Distrito Federal. México
2University of Tokyo, Tokio. Japón
Year:
Season: Dic
Volumen: 35
Number: 3
Pages: 253-262
Country: México
Language: Inglés
Document type: Artículo
Approach: Experimental, aplicado
Spanish abstract Las úlceras por presión son lesiones en la piel y tejidos subyacentes, causadas por presiones excesivas y prolongadas en las superficies de apoyo del cuerpo. Estas lesiones afectan principalmente a personas con poca movilidad física, como aquellas que permanecen sentados por largos periodos. Para disminuir el riesgo del padecimiento de estas lesiones, se ha recomendado como punto de partida reducir la magnitud y el tiempo de acción de las presiones en las zonas de apoyo. Se han desarrollado cojines dinámicos para sillas de ruedas, los cuales generan movimientos alternantes en las diferentes zonas de apoyo, producido por la inyección de aire, con el fin de disminuir las presiones en esas zonas. Sin embargo, no se han encontrado referencias de las características adecuadas de las secuencias de movimientos alternantes para prevenir la aparición de esas lesiones. El propósito de este trabajo es evaluar tres secuencias de movimientos alternantes diseñadas para un cojín de aire. La evaluación se realizó comparando la distribución de presiones en zonas de apoyo antes y durante la aplicación de estas secuencias alternantes en personas sanas. Las secuencias propuestas se aplican para el inflado y desinflado de celdas que forman el cojín y fueron diseñadas con el objetivo de distribuir las presiones en un área mayor de apoyo. La prueba se realizó en 8 sujetos sanos, con un tiempo de estudio de 12 minutos para cada secuencia diseñada; 2 minutos en modo estático y 10 minutos en modo alternante. Se propuso determinar el coeficiente de variación para evaluar de forma cuantitativa el efecto de las secuencias alternantes sobre la presión de interfaz. Además se calculó el porcentaje de variación relativa del coeficiente de variabilidad entre los modos basal (estático) y alternante como una herramienta para evaluar el desempeño de las secuencias propuestas en relación a la presión de interfaz. Se encontr
English abstract Pressure ulcers are injuries to the skin and/or underlying tissues caused by prolonged high pressures on supporting body areas, they affect mainly people with poor mobility that have stayed in seating position for a long time. Reducing the amount and duration of pressure has been widely accepted for minimizing the risk of formation of pressure ulcers. Recently, dynamic cushions have been developed to relieve pressure on supporting areas; nevertheless, there is no sufficient information about the adequate characteristics of alternating sequences for pressure ulcers prevention. Therefore, the aim of this work is to explore three sequences of alternating movements designed for an air cell cushion by comparing pressure redistribution on supporting areas when applied on healthy volunteers. The purpose of these sequences is to redistribute the pressure over a larger contact area. To evaluate the effect of the alternating sequences, eight healthy volunteers were asked to sit on the air cell cushion, and to try the three alternating sequences for 12 minutes, 2 minutes on static mode and 10 minutes on alternating mode. A parameter for quantitative assessment of alternating sequences was proposed in this work by determining the coefficient of variation of interface pressure. Furthermore, the percentage of relative change of coefficient of variation was computed for evaluating performance of the alternating sequences comparing to the static mode. It was found that the three proposed strategies maintained values of interface pressure lower than previous work. Additionally, the relative change allowed to differentiate the effects of alternation of each sequence showing the second strategy as the most effective. The results are encouraging for further studies in subjects who require a wheelchair for mobility
Disciplines: Medicina,
Ingeniería
Keyword: Terapéutica y rehabilitación,
Ingeniería biomédica,
Ulceras por presión,
Cojines dinámicos,
Distribución de presión,
Sillas de ruedas