Parâmetros eficientes do posicionamento adequado da ponta da agulha de veress durante o estabelecimento de pneumoperitônio



Document title: Parâmetros eficientes do posicionamento adequado da ponta da agulha de veress durante o estabelecimento de pneumoperitônio
Journal: Revista do Colegio Brasileiro de Cirurgioes
Database: PERIÓDICA
System number: 000283566
ISSN: 0100-6991
Authors: 1
2



Institutions: 1Hospital do Servidor Publico do Estado de Sao Paulo, Servico de Gastroenterologia Cirurgica, Sao Paulo. Brasil
2Universidade Federal de Sao Paulo, Departamento de Cirurgia, Sao Paulo. Brasil
Year:
Season: Jul-Ago
Volumen: 33
Number: 4
Pages: 220-223
Country: Brasil
Language: Portugués
Document type: Artículo
Approach: Experimental, caso clínico
English abstract BACKGROUND: To evaluate the possibility of establishing reliable parameters for the appropriate positioning of Veress needle tip in the peritoneal cavity during pneumoperitoneum creation. METHODS: In 100 selected patients Veress needle tip were introduced in the peritoneal cavity and the insufflators were programmed for a flow of 1,2L/min and with final maximum pressure of 12mmHg. At the beginning of the insufflation and at every 20 seconds the intraperitoneal pressure (IP) and the total volume injected (TVI) were recorded. Data was treated by statistical correlation between moments and IP, and moments and TVI. The forecast values of IP and TVI at the end of each one of the four first insufflation minutes were also established, using the following estimated formulas: IP = 2.3083 + 0.0266 x time + 8.3x10-5 x time³ - 2.44x10-7 x time³; TVI = 0.813 + 0.0157 x time. RESULTS: IP and TVI showed a correlation between pre-established moments of pneumoperitoneum creation when a strong adjustment became apparent: IP = -2E - 07 x time³ + 8E - 05 x time² + 0.0266 x time + 2.3083, with a coefficient of explanation: (R2) = 0.8011; TVI = 0.0157 x time + 0.1813, with R2=0.9604. The forecast of IP and TVI showed: IP (mmHg): 1min=4.15; 2 min=6.27; 3 min=8.36; 4 min=10.10 and TVI (L): 1min=1.12; 2 min=2.07; 3 min=3.01; 4 min=3.95. CONCLUSION: Reliable parameters for IP and TVI can be established during pneumoperitoneum creation when the Veress needle tip is located in the peritoneal cavity in a given insufflation moment
Portuguese abstract pneumoperitonio
Disciplines: Medicina
Keyword: Cirugía,
Punción,
Laparoscopia,
Técnicas quirúrgicas,
Neumoperitoneo
Keyword: Medicine,
Surgery,
Puncture,
Laparoscopy,
Surgical techniques,
Pneumoperitoneum