Estudio metodológico sobre la medición de pH y conductividad eléctrica en muestras de compost



Document title: Estudio metodológico sobre la medición de pH y conductividad eléctrica en muestras de compost
Journal: Revista Colombiana de Química
Database: PERIÓDICA
System number: 000435263
ISSN: 0120-2804
Authors: 1
2
1
3
Institutions: 1Queensborough Community College, Nueva York. Estados Unidos de América
2Universidad Nacional de Chimborazo, Facultad de Ingeniería, Riobamba, Chimborazo. Ecuador
3Universidad de Los Andes, Centro de Interamericano de Desarrollo e Investigaciones Ambientales y Territoriales, Mérida. Venezuela
Year:
Season: May-Ago
Volumen: 47
Number: 2
Country: Colombia
Language: Español
Document type: Artículo
Approach: Experimental, analítico
Spanish abstract En el presente trabajo se estudió la influencia de la relación compost/extractante sobre las mediciones de pH y conductividad eléctrica (CE) utilizando agua y una solución de CaCl2 0,01 M como extractantes, tanto en la suspensión como en el sobrenadante del extracto centrifugado. Los resultados muestran que la medición de pHCaCl2 es independiente de la cantidad de extractante a diferencia de la medición en extracto acuoso, que incrementa con la dilución y se ajusta más a una función polinómica. En consecuencia, la medición debe realizarse donde la pendiente curva sea mínima o nula y la medición sea más independiente de la cantidad de extractante. Esto ocurre en relaciones compost/extractante superior a 1:8 para el extracto acuoso y superior a 1:5 para el extracto de CaCl2. Igualmente, el pHH2O es menor que el pHCaCl2, por lo que este último es un mejor extractante de acidez y, por ende, más cercano a la realidad de la muestra. Las mediciones de CE también presentan un comportamiento polinómico, por lo que deben ser realizadas a relaciones compost/extractante mayores de 1:6, donde los valores de CE son más independientes de la cantidad de extractante, realizando la corrección del blanco respectivo
English abstract The present paper describes the influence of compost/solvent relations on pH and electric conductivity (CE) measurements, using water and CaCl2 0.01 M as extractants, in the extract suspension as well as in centrifuged supernatant. According to the results, pHCaCl2 seems to be more independent of extractant quantity, contrarily to aqueous extract measurements, which increases with dilution, described by a quadratic model. As a consequence, measurement must be performed where the curve slope is minimum or null, and where the measurement becomes independent of extractant quantity. For aqueous extract, it happens at relations compost/extractant greater than 1:8, and for CaCl2 extracts, greater than 1:5. pHH2O is higher than pHCaCl2 showing that CaCl2 is a better acidity extractant. EC measurements also show polynomical behavior, therefore must be performed on relations compost/extractant greater than 1:6, where EC values are more independent of extractant quantity. EC could be performed in CaCl2 extract, suspension or supernatant, with respective blank correction
Portuguese abstract No presente trabalho estudou-se a influenza de relação compostagem/extractante sobre as medições de pH e condutividade clétrica (CE) usando agua e uma solução de CaCl2 0,01 M como extractante, tanto na suspensão como no sobrenadante do extrato centrifugado. Os resultados mostram que a medição de pHCaCl2 é mais independente da quantidade de extractante, a diferencia da medição em extrato aquoso à qual ajusta-se mais a uma função polinómica. Em consequência, a medição deve ser feita onde a pendente curva é mínima ou nula, e a medição seja mais independente da quantidade de extractante. Isto acontece às relações compôs/extractante superiores à 1:8 para o extrato aquoso, e superior à 1:5 para extrato de CaCl2. Igualmente, o pHH2O é menor do que o pHCaCl2, pelo que este último é um melhor extractante de acidez, e por isso mais cercǎos à realidade da amostra. As medições de CE igualmente apresentam um comportamento polinómico, pelo qual devem ser feitas a relações compostagem/extractante maiores de 1:6, onde os valores de CE são mais independentes da quantidade de extractante, fazendo a correção do branco respectivo
Disciplines: Química
Keyword: Química analítica,
Composta,
Calidad,
pH,
Conductividad eléctrica
Keyword: Analytical chemistry,
Compost,
pH,
Quality,
Electric conductivity
Full text: Texto completo (Ver HTML) Texto completo (Ver PDF)