Estudio energético del sistema de bombeo en el Instituto de Ciencia Animal, Cuba



Document title: Estudio energético del sistema de bombeo en el Instituto de Ciencia Animal, Cuba
Journal: Revista ciencias técnicas agropecuarias
Database: PERIÓDICA
System number: 000416022
ISSN: 1010-2760
Authors: 1
1
1
1
2
Institutions: 1Instituto de Ciencia Animal, San José de las Lajas, Mayabeque. Cuba
2Universidad Agraria de La Habana "Fructuoso Rodríguez Pérez", San José de las Lajas, Mayabeque. Cuba
Year:
Season: Jul-Sep
Volumen: 25
Number: 3
Pages: 65-71
Country: Cuba
Language: Español, inglés
Document type: Nota breve o noticia
Approach: Analítico
Spanish abstract Con el objetivo de realizar un estudio energético del sistema de bombeo del Instituto de Ciencia Animal (ICA), se procedió a la mapificación y detección de salideros en la conductora principal, se midieron las fugas de agua en las redes interiores y se determinó el porciento de este líquido que se pierde por derroche. Conjuntamente se analizó el consumo energético de la bomba, se determinó la potencia real consumida y la eficiencia del motor. Los resultados demostraron que existen pérdidas de agua respecto al total que se bombea (1 400 m3), por mal uso (39,67%) y por mal estado técnico de las redes (31,76%). El estudio energético mostró que el consumo eléctrico anual de la institución por cuestión de abasto de agua es de 310 034.49 kW, lo que representa 67,6 toneladas equivalentes de petróleo, para un gasto anual de la institución de 71 962.38 USD. Se concluye que si se eliminan las pérdidas de agua, se evitan 5 horarios de bombeo, lo que representa un ahorro de 51 405.31 USD al año por dejar de importar 48,26 toneladas de petróleo, además se dejan de emitir a la atmósfera 131,75 t de CO2
English abstract In order to perform an energy study of the pumping system from the Institute of Animal Science, a mapping and detection study of leaks in the main conductor was conducted, water leakages were measured in the interior networks and the percentage of losses was determined. At the same time, an energy study of the pump was carried out and the actual consumed power and motor efficiency were determined. Results showed that there are great losses of water regarding the total pumped water (1 400 m3), due to misuse (39.67%) or bad technical state of the networks (31.76 %).The energy study showed that annual electric consumption of the institution, regarding water supply, is 310 034.49 kW, which represents 67.6 tons equivalent to oil and annual expenses of 71 962.38 USD for the institution. It can be concluded that removing water losses, five pumping times will be avoided, which represents a saving of 51 405.31 USD per year, because there are 48.26 tons of oil that are not imported. In addition, 131.75 t of CO2 would not be released to the atmosphere
Disciplines: Ingeniería
Keyword: Ingeniería ambiental,
Ingeniería eléctrica,
Ingeniería hidráulica,
Consumo de agua,
Consumo de energía,
Fugas,
Pérdidas,
Sustentabilidad
Keyword: Engineering,
Electrical engineering,
Environmental engineering,
Hydraulic engineering,
Water consumption,
Energy consumption,
Leaks,
Losses,
Sustainability