Calibration and standardization of air quality measurements using MQ sensors



Document title: Calibration and standardization of air quality measurements using MQ sensors
Journal: Respuestas
Database: PERIÓDICA
System number: 000444222
ISSN: 2422-5053
Authors: 1

1
Institutions: 1Universidad de Pamplona, Pamplona, Norte de Santander. Colombia
Year:
Season: Ene-Abr
Volumen: 25
Number: 1
Pages: 70-77
Country: Colombia
Language: Inglés
Document type: Artículo
Approach: Aplicado, descriptivo
Spanish abstract Para realizar la calibración y estandarización de las mediciones de la calidad del aire a través de los sensores MQ, se empleó una relación matemática con base en la información proporcionada por los fabricantes de los sensores a través de sus hojas de datos, utilizando el modelo de regresión matemática lineal que permitió crear las librerías para los sensores MQ-2, MQ-3, MQ-4, MQ-5, MQ-6, MQ-7, MQ-8, MQ-9, MQ-135, MQ-131, MQ-303A, MQ-309A, esas librerías se caracterizan por ser de código abierto, y están a disposición del público, cuya herramienta de software permite tomar valores en partes por millón(ppm) a partir del valor de la resistencia leída en el sensor, admite obtener datos los cuales son similares con otros estudios científicos dados que dan en las mismas unidades, las cuales sirven para realizar estudios en el medio ambiente, contaminación, análisis en procesos industriales
English abstract To perform the calibration and standardization of the air quality measurements through the MQ sensors, a mathematical relation was used based on the information provided by the manufacturers of the sensors through their data sheets, using the linear mathematical regression model that allowed to create the libraries for the sensors MQ-2, MQ-3, MQ-4, MQ-5, MQ-6, MQ-7, MQ-8, MQ-9, MQ-135, MQ-131, MQ-303A, MQ-309A, These libraries are characterized by being open source, and are available to the public, whose software tool allows to take values in parts per million (ppm) from the value of the resistance read in the sensor, allows to obtain data which are similar to other scientific studies given that they give in the same units, which serve to perform studies in the environment, pollution, analysis in industrial processes
Disciplines: Ingeniería
Keyword: Ingeniería de control,
Ingeniería ambiental,
Calidad del aire,
Sensores,
Calibración,
Datos de ajuste,
Arduino
Keyword: Control engineering,
Environmental engineering,
Air quality,
Sensors,
Calibration,
Fitting data,
Arduino
Full text: https://revistas.ufps.edu.co/index.php/respuestas/article/view/2408/3008