Journal: | Quimica nova |
Database: | PERIÓDICA |
System number: | 000196324 |
ISSN: | 0100-4042 |
Authors: | Moreno, Ruben G.M1 Oliveira, Elisabeth de Oliveira, Pedro V Pedrotti, Jairo J |
Institutions: | 1Universidade Presbiteriana Mackenzie, Faculdade de Ciencias Biologicas, Exatas e Experimentais, Sao Paulo. Brasil |
Year: | 2001 |
Season: | May-Jun |
Volumen: | 24 |
Number: | 3 |
Pages: | 404-407 |
Country: | Brasil |
Language: | Portugués |
Document type: | Artículo |
Approach: | Experimental |
English abstract | A flow cell assembled on the original geometry of a graphite tube to achieve permanent chemical modifier is proposed. The graphite tube operates as the working electrode. A stainless steel tube, positioned downstream from the working electrode, was used as the auxiliary electrode. The potential value applied on the graphite electrode was measured against a micro reference electrode (Ag/AgCl) inserted into the auxiliary electrode. Palladium solutions in acetate buffer (100 mmol L-1, pH = 4.8), flowing at 0.5 mL min-1 for 60 min was used to perform the electrochemical modification. A mercury solution (1 ng) was used to evaluate the performance of the permanent palladium modifier |
Disciplines: | Química |
Keyword: | Química analítica, Electroquímica, Celdas electroquímicas, Grafito, Absorción atómica, Modificador permanente |
Keyword: | Chemistry, Analytical chemistry, Electrochemical, Electrochemical cell, Graphite, Atomic absorption, Permanent modifier |
Full text: | Texto completo (Ver HTML) |