Comparative Bilateral Bone Density of the Mandible Angle



Document title: Comparative Bilateral Bone Density of the Mandible Angle
Journal: International journal of morphology
Database: PERIÓDICA
System number: 000327220
ISSN: 0717-9502
Authors: 1
1
1
1
1
Institutions: 1Universidade de Sao Paulo, Faculdade de Odontologia de Ribeirao Preto, Ribeirao Preto, Sao Paulo. Brasil
Year:
Season: Jun
Volumen: 25
Number: 2
Pages: 337-340
Country: Chile
Language: Inglés
Document type: Nota breve o noticia
Approach: Descriptivo
Spanish abstract El objetivo de este estudio fue realizar una comparación bilateral de la densidad de mandíbula en pacientes jóvenes de ambos sexos con computadora densitométrica ósea. Fueron obtenidas 50 radiografías panorámicas de pacientes jóvenes entre 18 y 23 años de edad (Grupo A = 25 femenino y el grupo B = 25 masculino), utilizando el mismo equipo de radiografía (Siemens, 1 OKvp, 7mA). Se escaneó con una resolución de 282,110 pixels, transfiriéndose luego a un computador para el estudio por medio del programa SIDEXIS (Sirona, USA) para analizar el desempeño densitométrico de hueso. Los sitios bilaterales fueron estandarizados con el objetivo de medir la densidad de hueso. Los datos obtenidos fueron registrados y sometidos a análisis estadístico. Las medias y los desvíos padrón fueron obtenidos en pixels, para el lado derecho y el lado izquierdo, respectivamente: Grupo A = 154,36±36,90 y 186,12±31,41, grupo B = 162,07±34,94 y 180,15±30,96. Estos valores muestran la diferencia estadística entre lados y grupos diferentes (p<0,05), con una densidad más alta de hueso en el lado izquierdo en ambos grupos, especialmente en grupo A
English abstract The aim of this study was to assess a bilateral comparison of the mandible density in both sex young patients with computer densitometry. Fifty panoramic radiographs were obtained from young patients with ages between 18 and 23 years old (group A = 25 female and group B = 25 male) standardized, using the same X-Ray equipment (Siemens, lOKvp, 7mA), scanned with a 282.110 pixels resolution, and transferred later to a computer and using the SIDEXIS (Sirona, USA) program to analyze the bone densitometry performance. Bilateral sites were standardized with the objective to measure the bone density. Obtained data were registered and submitted to statistical analysis. The following means and standard deviations were obtained, in pixels, for the right and the left side, respectively: group A= 154.36±36.90 e 186.12+31.41, group B= 162.07±34.94 and 180.15+30.96. These values show statistical difference between different sides and groups (p<0.05), with a higher bone density on the left side in both groups, especially in group A
Disciplines: Medicina
Keyword: Anatomía humana,
Odontología,
Mandíbula,
Densidad ósea,
Angulo,
Género
Keyword: Medicine,
Dentistry,
Human anatomy,
Mandible,
Bone density,
Angle,
Gender
Full text: Texto completo (Ver HTML)