DC resistivity investigation in a fractured aquifer system contaminated by leachate from an old dump



Document title: DC resistivity investigation in a fractured aquifer system contaminated by leachate from an old dump
Journal: Geofísica internacional
Database: PERIÓDICA
System number: 000446897
ISSN: 0016-7169
Authors: 1
2
2
2
Institutions: 1Universidade Estadual Paulista "Julio de Mesquita Filho", Instituto de Geociencias e Ciencias Exatas, Rio Claro, Sao Paulo. Brasil
2Universidade Federal do Pampa, Cacapava do Sul, Rio Grande do Sul. Brasil
Year:
Season: Oct-Dic
Volumen: 56
Number: 4
Pages: 345-358
Country: México
Language: Inglés
Document type: Artículo
Approach: Analítico, descriptivo
Spanish abstract Los basureros son zonas de depósito final de desechos sólidos directamente en el suelo, en ausencia de criterios técnicos o sistemas de recolección de gases o líquidos. Una gran parte de los municipios brasileños han utilizado esta alternativa extremadamente perjudicial para el ambiente hasta el año 2010, cuando una ley federal hizo obligatoria la instalación de rellenos sanitarios. Sin embargo, una gran parte de los basureros fueron simplemente abandonados, aunque algunos finalmente tuvieron algún tratamiento después de las evaluaciones de los organismos ambientales. Este trabajo presenta los resultados de la investigación geofísica en un basurero cerrado en 2004 en una pequeña ciudad del sur de Brasil, donde las investigaciones anteriores revelaron contaminaciones del suelo y de las aguas subterráneas por lixiviación. Los análisis estructurales en la región de estudios vinculados a datos geológicos de pozos de monitoreo indican la presencia de contaminantes en la fractura de granito, con amplias variaciones en el espesor del suelo, saprolita y el nivel del agua subterránea. La integración del análisis químico de las aguas subterráneas con los datos de la tomografía eléctrica (ERT) en el procesamiento de imágenes 2D y 3D, reveló la existencia de grandes áreas contaminadas dentro de los límites del basurero y el flujo en el acuífero parcialmente libre hasta 5m de profundidad. Estas zonas pueden disminuir gradualmente con el aumento de la profundidad y entre 9m y 19m predominan zonas contaminadas claramente orientadas, asociada con el flujo en el acuífero fracturado. La indicación de zonas restringidas y dirigidos sugiere la focalización y la acumulación de contaminantes en los dos sistemas de fracturas preferenciales. El descubrimiento de estas áreas es esencial para la planificación y la instalación de sistemas de bombeo y de descontaminación de aguas subterráneas, en vista de la disminución de la producción de li
English abstract The dumps are areas of final disposal of solid wastes directly into the soil, with no technical criteria or collecting systems of gases or liquids. A large part of Brazilian municipalities have used this extreme damaging alternative to the environment up to the year 2010, when a federal law made compulsory the installation of sanitary landfills. However, large parts of the dumps were simply abandoned, although some eventually go through treatment after assessments of the state environmental agencies. This work presents the results of a geophysical investigation in a dump deactivated in 2004 in a small city in southern Brazil, where previous investigations have revealed contamination of soil and groundwater by leachate. Structural analyzes in the area of study combined to geological data from monitoring wells indicate the presence of contaminants in fractured granite, with a wide variation in the thickness of soil, saprolite and groundwater level. The integration of chemical analyses of the groundwater with electrical resistivity tomography (ERT) in 2D and 3D processing, revealed the existence of large contaminated areas within the limits of the dump flowing into the aquifer partially free up to 5m depth. Such areas may decrease gradually with the increase in depth and between 9m and 19m contaminated zones clearly predominate, associated with the Flow in the fractured aquifer. The indication of restricted and oriented zones suggests the targeting and accumulation of contaminants in two systems of preferential fractures. The discovery of these zones is fundamental for planning and the installation of pumping and decontamination systems of groundwater, considering a declining production of leachate since the closure of the dump
Disciplines: Geociencias
Keyword: Geofísica,
Materia orgánica,
Lixiviación,
Contaminación,
Acuífero fracturado,
Tomografia eléctrica
Keyword: Geophysics,
Organic matter,
Bleaching,
Contamination,
Fractured aquifer,
Electric resistivity tomography
Full text: Texto completo (Ver HTML) Texto completo (Ver PDF)