Thermal assessment of ecological tiles in physical models of poultry houses1



Document title: Thermal assessment of ecological tiles in physical models of poultry houses1
Journal: Dyna (Medellín)
Database: PERIÓDICA
System number: 000395004
ISSN: 0012-7353
Authors: 1
1
1
2
3
Institutions: 1Universidade Federal de Lavras, Departamento de Engenharia, Lavras, Minas Gerais. Brasil
2Universidad Nacional de Colombia, Facultad de Ciencias Agrarias, Medellín, Antioquia. Colombia
3Universidade Federal de Mato Grosso, Departamento de Engenharia Agricola, Cuiaba, Mato Grosso. Brasil
Year:
Season: Jun
Volumen: 83
Number: 197
Pages: 114-119
Country: Colombia
Language: Inglés
Document type: Artículo
Approach: Aplicado, descriptivo
Spanish abstract En países con climas tropicales, como Brasil, las altas temperaturas asociadas con altas humedades relativas en el verano contribuyen como un factor de estrés en la producción animal. El calor excesivo dentro de una instalación avícola causa una reducción en el consumo de alimento y en la producción, y aumento en la mortalidad de las aves. Conociendo que el 75% de la carga de calor radiante dentro de una instalación viene desde el techo, es necesario estudiar alternativas que pueden minimizar esta radiación. El objetivo del presente trabajo fue analizar el ambiente térmico dentro de los modelos físicos de instalaciones de pollos de engorde construidos a escala reducida (1:10), donde el confort térmico se evaluó por el índice de humedad y de globo negro (BGHI) y la carga de calor radiante (RHL). Cinco modelos construidos fueron evaluados con diferentes materiales para techos. Basados en los resultados, se puede concluir que los techos construidos con tejas de cerámica (TB30), placas de fibra natural pintadas de blanco con en el lado externo (TFVP15) y placas de fabricadas con envases larga vida reciclado (TLV15), proporcionan los mejores ambientes térmicos
English abstract In countries with tropical climates, such as Brazil, the high summer temperatures associated with high relative humidities are a stress factor in animal production. Excessive heat within a poultry facility causes a reduction in feed intake and production, and increased bird mortality. With the knowledge that about 75% of the radiant heat load within a facility comes from the roof, it is necessary to study alternatives that can minimize this radiation. Thus, the objective of the present work is to analyze the thermal environment inside physical broiler housing models constructed on a reduced scale (1:10), where the thermal comfort was evaluated by the black globe humidity index (BGHI) and radiant heat load (RHL). Five models built with different roofing materials were evaluated. Based on the results, it can be concluded that roofs constructed with the channel clay roofing tile (TB30), natural fiber tiles with their external side painted white (TFVP15) and tiles made of recycled long-life packaging (TLV15), provide better thermal environments within the models
Disciplines: Ingeniería,
Medicina veterinaria y zootecnia
Keyword: Ingeniería civil,
Aves de corral,
Gallineros,
Confort térmico,
Tejas,
Evaluación térmica
Keyword: Engineering,
Veterinary medicine and animal husbandry,
Civil engineering,
Poultry,
Poultry houses,
Thermal comfort,
Tiles,
Thermal evaluation
Full text: Texto completo (Ver PDF)