Journal: | Dyna (Medellín) |
Database: | |
System number: | 000537539 |
ISSN: | 0012-7353 |
Authors: | Pulgarín Montoya, Diego Alejandro1 De Plaza S., Juan Sebastián1 Ruge C., Juan Carlos1 Rocha de Albuquerque, Paulo José2 |
Institutions: | 1Universidad Católica de Colombia, Facultad de Ingeniería, Bogotá DC. Colombia 2Universidade Estadual de Campinas, Departamento de Geotecnia e Transportes, Campinas, São Paulo. Brasil |
Year: | 2021 |
Season: | Oct-Dic |
Volumen: | 88 |
Number: | 219 |
Pages: | 28-34 |
Country: | Colombia |
Language: | Inglés |
Spanish abstract | En este estudio se determina el grado de bondad de ajuste que presenta el modelo de San para el cálculo del porcentaje de remoción de partículas floculentas, cuando la turbiedad inicial en el agua problema es baja. Para esto, se hace el análisis de frecuencia de los datos históricos de turbiedad que ingresan a cuatro plantas de tratamiento de agua potable ubicadas en el departamento de Cundinamarca (Colombia), las cuales arrojan valores que oscilan entre 0.60 y 15.08 UNT (Unidades Nefelométricas de Turbidez). La coagulación del agua se hizo utilizando sulfato de aluminio tipo A y la prueba de sedimentación se realizó en una torre de sedimentación con el fin de determinar la turbiedad remanente en el agua que permite calcular el porcentaje de remoción para diferentes tiempos de sedimentación y a distintas profundidades. |
English abstract | In this study, the degree of goodness of fit presented by the San model is determined to calculate the percentage of removal of flocculent particles, when the initial turbidity in the problem water is low. For this, the frequency analysis of the historical turbidity data that enters four drinking water treatment plants located in the department of Cundinamarca (Colombia) is made, which show values that range between 0.60 and 15.08 NTU (Nephelometric Turbidity Units). The water coagulation was done using type A aluminum sulfate and the sedimentation test was carried out in a sedimentation tower in order to determine the remaining turbidity in the water, which allows calculating the percentage of removal for different sedimentation times and at different depths. The values of the constants of the San model were determined through a multiple linear regression and the goodness of fit test was performed by calculating the coefficient of determination R2 for the different initial turbidity values in the test water. |
Keyword: | Coagulación, Floculación, Sedimentación, Curvas de isoconcentración |
Keyword: | Coagulation, Flocculation, Sedimentation, Isoconcentration curves |
Full text: | Texto completo (Ver HTML) Texto completo (Ver PDF) |