Ferrite Loaded DBD Plasma Device



Document title: Ferrite Loaded DBD Plasma Device
Journal: Brazilian journal of physics
Database: PERIÓDICA
System number: 000385169
ISSN: 0103-9733
Authors: 1
Institutions: 1Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin", Campinas, Sao Paulo. Brasil
Year:
Season: Feb
Volumen: 45
Number: 1
Pages: 132-137
Country: Brasil
Language: Inglés
Document type: Artículo
Approach: Experimental, aplicado
English abstract An atmospheric pressure plasma jet device with dielectric barrier discharge was built using low cost 5C22 thyratron valve and ferrite transformer. The ferrite transformer increases the intensity about four times the primary pulse and lengthens the high voltage pulse, keeping the rise time of the thyratron pulse. Spectrometer measurement shows excited nitrogen molecular emissions of second positive system. The most intense nitrogen molecular line, 357.69 nm, was chosen to monitor the time dependence of the discharge. Synthetic temperature, using 380.49 nm line of N2 emission and SpecAir simulation, shows plasma gas temperature of 300 K. To corroborate this low temperature, the plasma jet is applied to human tongue with no harm or bad physical feeling
Disciplines: Física y astronomía
Keyword: Teoría cinética y plasmas,
Jet atmosférico de plasma,
Válvula de thyratron,
Transformadores de ferrita,
Temperatura sintética,
Descarga dialéctrica de barrera
Keyword: Physics and astronomy,
Kinetic theory and plasma,
Atmospheric plasma jet,
Thyratron valve,
Ferrite transformer,
Synthetic temperature,
Dielectric barrier discharge
Full text: Texto completo (Ver HTML)