Validez y confiabilidad de una escala de valoración de comportamientos de autocuidado en personas con falla cardiaca



Document title: Validez y confiabilidad de una escala de valoración de comportamientos de autocuidado en personas con falla cardiaca
Journal: Aquichan
Database: PERIÓDICA
System number: 000378801
ISSN: 1657-5997
Authors: 1
1
Institutions: 1Universidad de Antioquia, Medellín, Antioquia. Colombia
Year:
Season: Abr
Volumen: 12
Number: 1
Pages: 23-31
Country: Colombia
Language: Español
Document type: Artículo
Approach: Analítico, descriptivo
Spanish abstract Objetivo: determinar la validez y confiabilidad, en el contexto colombiano, de la Escala de valoración de comportamientos de autocuidado en personas con falla cardiaca (FC) diseñada por Nancy Artinian. Método: estudio de validación de la escala Revised Heart Failure Self Care Behavior. Se realizó validación cultural (n = 13 enfermeros expertos en cuidado cardiovascular y 12 pacientes con FC), validación factorial y análisis de la confiabilidad (n = 206 pacientes con FC). Resultados: la validación cultural de la escala fue adecuada. La validación factorial mostró que la versión en español tenía cuatro dominios (solicitud de ayuda, adaptación a vivir con la enfermedad, adherencia al tratamiento farmacológico y adherencia al tratamiento no farmacológico) que explicaron el 34,2% de la varianza del constructo latente en la escala. Se eliminaron siete ítems por explicar menos del 0,2% de la varianza, quedando la escala final reducida a 21 ítems. El coeficiente de confiabilidad alfa de Cronbach para la escala total fue aceptable (0,75). Conclusión: la nueva versión de la escala tiene adecuadas propiedades psicométricas en términos de confiabilidad y validez, lo que permitirá su utilización por enfermeros en la detección de cambios de comportamientos de autocuidado clínicamente importantes en los pacientes con FC
English abstract Objective: The purpose of this study is to determine the validity and reliability, in the Colombian context, of a scale designed by Nancy Artinian to rate self-care among persons with heart failure (HF). Method: This is a validation study of the Revised Heart Failure Self-care Behavior Scale. A cultural validation was done (n = 13 nurses who are experts in cardiovascular care and 12 patients with HF), along with factor validation and a reliability analysis (n = 206 patients with HF). Results: The cultural validation of the scale was adequate. The factor evaluation showed the Spanish version had four domains (asking for help, adapting to living with the disease, adherence to pharmacological treatment, and adherence to non-pharmacological treatment) that explained 34.2% of the latent construct variance in the scale. Seven items that account for less than 0.2% of the variance were eliminated, leaving the final scale reduced to 21 items. The Cronbach alpha reliability coefficient for the entire scale was acceptable (0.75). Conclusion: The new version of the scale has adequate psychometric properties in terms of reliability and validity, allowing for its use by nurses to detect clinically important behavioral changes in self-care among patients with HF
Portuguese abstract Objetivo: determinar a validade e confiabilidade, no contexto colombiano, da Escala de valoração de comportamentos de autocuidado em pessoas com falha cardíaca (FC) desenhada por Nancy Artinian. Método: estudo de validação da escala Revised Heart Failure Self Care Behavior. Realizou-se validação cultural (n = 13 enfermeiros especialistas em cuidado cardiovascular e 12 pacientes com FC), validação fatorial e análise da confiabilidade (n = 206 pacientes com FC). Resultados: a validação cultural da escala foi adequada. A validação fatorial mostrou que a versão em espanhol tinha quatro domínios (solicitação de ajuda, adaptação para viver com a doença, aderência ao tratamento farmacológico e aderência ao tratamento não farmacológico) que explicaram os 34,2% da variação do construto latente na escala. Eliminaram-se sete itens por explicar menos de 0,2% da variação, ficando a escala final reduzida a 21 itens. O coeficiente de confiabilidade alfa de Cronbach para a escala total foi aceitável (0,75). Conclusão: a nova versão da escala tem adequadas propriedades psicométricas em termos de confiabilidade e validade, o que permitirá sua utilização por enfermeiros na detecção de mudanças de comportamentos de autocuidado clinicamente importantes nos pacientes com FC
Disciplines: Medicina
Keyword: Sistema cardiovascular,
Terapéutica y rehabilitación,
Enfermería,
Falla cardiaca,
Autocuidado,
Estudios de validación
Keyword: Medicine,
Cardiovascular system,
Therapeutics and rehabilitation,
Nursery,
Heart failure,
Self-care,
Validation studies