Tomografía computada: grandes beneficios con gran responsabilidad



Document title: Tomografía computada: grandes beneficios con gran responsabilidad
Journal: Acta médica Grupo Angeles
Database: PERIÓDICA
System number: 000398902
ISSN: 1870-7203
Authors: 1
1
Institutions: 1Universidad La Salle, México, Distrito Federal. México
Year:
Season: Oct-Dic
Volumen: 13
Number: 4
Pages: 232-237
Country: México
Language: Español
Document type: Artículo
Approach: Aplicado, analítico
Spanish abstract En la actualidad, los estudios tomográficos se consideran casi una rutina debido a su amplia disponibilidad y precisión diagnostica; sin embargo, aunque en los tiempos modernos la radiación ionizante emitida por este método de imagen ha disminuido, su uso debe ser responsable y apegado a una buena práctica. El objetivo de este artículo es conocer las dosis de radiación a las que están expuestos los pacientes en tomografías realizadas por médicos en formación y comparar las dosis efectivas obtenidas con las recomendadas por la Asociación Americana de Físicos en Medicina. Se calcularon las dosis efectivas de 419 estudios tomográficos de diferentes áreas corporales realizadas con un tomógrafo General Electric Lightspeed Ultra de 16 cortes por médicos residentes de primero y segundo año en un lapso de ocho meses. Los valores de las dosis efectivas se sobrepasaron en 25.7% de los estudios, con una media de 3.1 mSv por encima de las recomendaciones de las guías internacionales, obteniéndose un mayor índice de sobreexposición en los estudios de cráneo contrastado. Médicos y técnicos radiólogos deben apegarse a los principios de protección radiológica para disminuir el riesgo de efectos estocásticos, realizando una práctica responsable y evitando la sobreexposición
English abstract Nowadays, tomographic studies are considered almost routine due to their wide availability and diagnostic accuracy. Nevertheless, even through the ionizing radiation emitted by this imaging method is deemed low, their usage must be responsible and attached to good practice to avoid overexposure. This article was designed to know the radiation dose to which patients are exposed during CT scans performed by resident physicians in their training and compare the effective doses obtained with those recommended by the American Association of Physicists in Medicine. The effective doses of 419 tomographic studies of different body areas practiced by resident physicians with a General Electric scanner Lightspeed Ultra 16 beams were calculated. The imaging studies were performed on a population ranging between one and 102 years of age, with an average of 52.7 years. The values of the effective doses were surpassed in 25.7% of the studies, with an average of 3.1 mSv above the recommendations of the international guidelines. The highest rate of overexposure was observed in contrast cranial studies. Radiologist physicians and technologists must improve the technique according to the principles of radiation safety to diminish stochastic risks, raising awareness of radiation exposure for a responsible usage of diagnostic CT scans
Disciplines: Medicina
Keyword: Diagnóstico,
Terapéutica y rehabilitación,
Tomografía,
Dosis,
Radiación ionizante,
Exposición,
Guías clínicas,
Protección radiológica
Keyword: Medicine,
Diagnosis,
Therapeutics and rehabilitation,
Tomography,
Dose,
Ionizing radiation,
Exposition,
Clinical guides,
Radiological protection
Full text: Texto completo (Ver PDF)