Is CO2 gas unsufflator necessary for laparoscopic training in animals?



Document title: Is CO2 gas unsufflator necessary for laparoscopic training in animals?
Journal: Acta cirurgica brasileira
Database: PERIÓDICA
System number: 000286190
ISSN: 0102-8650
Authors: 1







Institutions: 1Universidade de Sao Paulo, Faculdade de Medicina, Ribeirao Preto, Sao Paulo. Brasil
Year:
Volumen: 18
Pages: 8-10
Country: Brasil
Language: Inglés
Document type: Artículo
Approach: Experimental
English abstract R$ 3,150.00 (U$ 1,050.00). The mean length time of surgeries in groups A, B and C were respectively: 181±30min, 196±39min e 210±47min (p>0.05). Respiratory alkalosis occurred in 3 out of 5 pigs of group C. No animal exhibited signs of gas embolism or died during surgery. CONCLUSION: The use of compressed air for laparoscopy in pigs was safe, reduced costs and did not require the use of an automatic gas insufflator
Portuguese abstract R$ 3.150,00 no grupo A. A duração média da cirurgia nos grupos A, B e C foram respectivamente: 181±30min, 196±39min e 210±47min (p>0.05). Alcalose respiratória foi observada em 3/5 porcos testados do grupo C. Nenhum animal apresentou sinais de embolia gasosa ou faleceu durante o procedimento. CONCLUSÃO: O uso de ar comprimido para laparoscopias em porcos mostrou-se método seguro com redução de custos e tornou desnecessário o uso de insuflador automático
Disciplines: Medicina
Keyword: Cirugía,
Medicina experimental,
Pieloplastia,
Nefrectomía,
Neumoperitoneo,
CO2,
Aire comprimido,
Laparoscopia
Keyword: Medicine,
Experimental medicine,
Surgery,
Nephrectomy,
Pyeloplasty,
Pneumoperitoneum,
CO2,
Compressed air,
Laparoscopy
Full text: Texto completo (Ver HTML)