Resumen en español JUSTIFICATIVA Y OBJETIVOS: Las cánulas de dupla luz pueden imponer distintas resistencias al flujo. Esta disparidad puede ocasionar ventilación pulmonar no homogénea. El objetivo de este trabajo es comparar el patrón resistivo de la cánula de intubación de dupla luz 37 FR con las cánulas convencionales, utilizadas en nuestro medio, cuando sometidas a flujos diferentes. MÉTODO: Fueron utilizadas cánulas de intubación orotraqueal con diámetros internos de 7, 7,5, 8 y 8,5 mm y de dupla luz 37 FR. Los flujos fueron generados y mantenidos por aparato de anestesia. La presión resistiva generada en las cánulas fue aferida por un pneumotacógrafo de orificio variable y convertida para sistema digital. Las resistencias fueron obtenidas dividiéndose las presiones medidas por los flujos empleados. Los datos fueron sometidos a un análisis de variancia (ANOVA) y comparados por el test de Tukey. RESULTADOS: Fueron registradas cinco medidas obtenidas aleatoriamente. Todas las cánulas estaban abiertas para el medio-ambiente. Resistencias están en cmH2O.L-1.s-1. La resistencia aumenta de forma linear con elevación del flujo. La cánula 37 FR dupla luz mostró patrón resistivo semejante al de la cánula con diámetro interno de 7,5 mm. La oclusión de los ramos de la sonda 37 FR eleva significativamente la resistencia al flujo. Los flujos de 0,1 a 0,2 L.s-1 resultaron en presiones resistivas semejantes para una misma sonda de intubación, excepto para cánula 7 mm o para la 37 FR con oclusión (p < 0,001). CONCLUSIONES: Los patrones resistivos de las cánulas 37 FR y 7,5 mm se mostraron bastante próximos. La oclusión de algún ramo de la sonda de dupla luz eleva significativamente la resistencia, más de modo indistinto entre ambos ramos para flujos abajo de 0,5 L.s-1. Los resultados del presente estudio sugieren la reducción de flujos inspiratorios como parámetro para disminuir la resistencia del sistema de ven
Resumen en inglés BACKGROUNG AND OBJECTIVES: Double lumen tubes may determine different flow resistances. This disparity may result in non-homogeneous ventilation. This study aimed at comparing the resistive pressure of 37 FR double lumen tubes to distinct flows as compared to conventional adult tracheal tubes. METHODS: Tracheal tubes with internal diameters of 7; 7.5; 8 and 8.5 millimeters (mm) and 37 FR double lumen tubes were tested. Flows were generated and maintained by a conventional anesthesia ventilator. Resistive pressure generated in the tubes was measured by a variable inlet pneumotachograph and converted to a digital system. Resistances were obtained by dividing measured pressures by flows. Data were submitted to analysis of variance (ANOVA) and Tukey’s test. RESULTS: Five independent measurements were obtained. All tubes were opened to the environment. Resistances are shown in cmH2O.L-1.s-1. Resistance is linearly increased with increased flow. The 37 FR tube had a resistive pattern similar to the 7.5 mm tracheal tube. The occlusion of any double lumen branch significantly increases flow resistance. Flows set at 0.1 L.s-1 to 0.2 L.s-1 resulted in similar resistive pressures for all tubes, except for the 7 mm or the occluded 37 FR tube (p < 0.001). CONCLUSIONS: Resistive patterns of 37 FR and 7,5 mm tubes were very similar. Any double lumen branch occlusion significantly increases resistance, however in a similar way for both branches for flows below 0.5 L.s-1. These results suggest the use of low inspiratory flow to minimize ventilatory system resistive pressure when any branch of a double-lumen tube is occluded
Resumen en portugués JUSTIFICATIVA E OBJETIVOS: As cânulas de dupla luz podem impor resistências distintas ao fluxo. Esta disparidade pode acarretar ventilação pulmonar não homogênea. O objetivo deste trabalho é comparar o padrão resistivo da cânula de intubação de dupla luz 37 FR com o das cânulas convencionais, utilizadas em nosso meio, quando submetidas a fluxos diferentes. MÉTODO: Foram utilizadas cânulas de intubação orotraqueal com diâmetros internos de 7, 7,5, 8 e 8,5 mm e de dupla luz 37 FR. Os fluxos foram gerados e mantidos por aparelho de anestesia. A pressão resistiva gerada nas cânulas foi aferida por um pneumotacógrafo de orifício variável e convertida para sistema digital. As resistências foram obtidas dividindo-se as pressões medidas pelos fluxos empregados. Os dados foram submetidos à análise de variância (ANOVA) e comparados pelo teste de Tukey. RESULTADOS: Foram registradas cinco medidas obtidas aleatoriamente. Todas as cânulas estavam abertas para o meio-ambiente. Resistências estão em cmH2O.L-1.s-1. A resistência aumenta de forma linear com elevação do fluxo. A cânula 37 FR dupla luz mostrou padrão resistivo semelhante ao da cânula com diâmetro interno de 7,5 mm. A oclusão dos ramos da sonda 37 FR eleva significativamente a resistência ao fluxo. Os fluxos de 0,1 a 0,2 L.s-1 resultaram em pressões resistivas semelhantes para uma mesma sonda de intubação, exceto para cânula 7 mm ou para a 37 FR com oclusão (p < 0,001). CONCLUSÕES: Os padrões resistivos da cânulas 37 FR e 7,5 mm mostraram-se bastante próximos. A oclusão de algum ramo da sonda de dupla luz eleva significativamente a resistência, mas de modo indistinto entre ambos ramos para fluxos abaixo de 0,5 L.s-1. Os resultados do presente estudo sugerem a redução de fluxos inspiratórios como parâmetro para diminuir a resistência do sistema de ventilação, quando um dos lumens de um tubo de dupla luz for obstru