Morphometric analysis of the infraorbital foramen and acessories foraminas in brazilian skulls



Título del documento: Morphometric analysis of the infraorbital foramen and acessories foraminas in brazilian skulls
Revista: International journal of morphology
Base de datos: PERIÓDICA
Número de sistema: 000268062
ISSN: 0717-9502
Autores: 1




1
Instituciones: 1Universidade Federal Fluminense, Instituto de Biomedicina, Rio de Janeiro. Brasil
Año:
Periodo: Dic
Volumen: 22
Número: 4
País: Chile
Idioma: Español
Tipo de documento: Artículo
Enfoque: Descriptivo
Resumen en español El objetivo del estudio fue establecer morfométricamente la localización del agujero infraorbital (FIO) en los planos sagital y transversal del cráneo y analizar las variaciones, así como verificar la simetría con el FIO contralateral. Fueron analizados 210 cráneos de individuos adultos. Utilizamos un paquímetro digital para efectuar las dos mediciones: a) sagital: del borde infraorbital hasta el borde superior del FIO; b) transversal: del borde lateral de la abertura piriforme hasta el bordemedial del FIO, utilizando el plano transversal. Estas mediciones forman un ángulo de 90 entre sí. Los datos fueron analizados por Kolmogorov-Smirnov y prueba de Person para evaluar la correlación, considerando un p 0.05. La media y ± SD en la distancia sagital fueron en el lado derecho 6,71± 1.70 mm y en el lado izquierdo 6,83±1.83 mm (p0.0001). Las medidas transversales fueron: lado derecho 13.28±2.17 mm y lado izquierdo 13.31±2.19 mm (p0.0001). Fueron observadas foraminas supranumerarias del FIO, con la presencia del IOF doble en 50 casos, siendo bilaterales en 8 especímenes izquierdos y derechos de la cara, 21 para cada lado. El FIO no era absolutamente simétrico y podía presentar el par bilateral y la abertura unilateral. La presencia de foraminas supranumerarias, como diversas medidas de este estudio, pueden interferir con la anestesia. Así sugerimos considerar estos parámetros en la evaluación anestésica y recordar las variantes durante los procedimientos usados para la localización del agujero infraorbital
Resumen en inglés The aim of the study was to establish morphometrically the infraorbital foramen (IOF) location in the sagittal and transversal plan of the skull and to analyze the variations, as well as verifying the symmetry with the contralateral IOF. 210 skulls were analyzed and as exclusion criterion, were not analyzed skulls of children. Digital paquimeter was used and had been carried through two bilateral measures: a)sagittal measure; from infraorbital margin until the superior margin of the IOF; b) transversal measure, of the lateral margin of piriformis opening until the medial margin of the IOF, using the transversal plan. These measures had formed an angle of 90 between itself. The data were analyzed by the Kolmogorov-Smirnov to verify the Gaussian distribution and and Person's test to evaluate the correlation, considering significantly the differences that had presented a p 0,05. The mean±SD in the sagital measures were respectively; right side 6,71±1.70 mm and 6,83±1.83 mm for left side (p0.0001). Transversal measures were: right side 13,28±2.17mm and 13,31±2.19 mm for left side (p0.0001). Were observed supranumerary foramens of the IOF, with presence of the double IOF in 50 cases, being bilateral in 08 specimens, left and right side 21 specimens for each side.The IOF are not absolutely symmetrical and may present pair bilateral and or unilateral opening. The presence of the supranumerary foraminas, as well as, the morphometrics measures in this study may intervene with the anesthesia, thus, suggest that they must be considered in the anaesthesical evaluation and be remembered during the procedures used for the localization of the forame
Disciplinas: Medicina
Palabras clave: Anatomía humana,
Cráneo,
Morfometría,
Agujeros infraorbitales
Keyword: Medicine,
Human anatomy,
Skull,
Morphometry,
Infraorbital foramen
Texto completo: Texto completo (Ver HTML)