Human error and response to alarms in process safety



Título del documento: Human error and response to alarms in process safety
Revista: Dyna (Medellín)
Base de datos: PERIÓDICA
Número de sistema: 000394998
ISSN: 0012-7353
Autores: 1
2
1
2
Instituciones: 1Poznan University of Technology, Faculty of Engineering Management, Poznan. Polonia
2Buskerud and Vestfold University College, Department of Maritime Technology and Innovation, Borre, Horten. Noruega
Año:
Periodo: Jun
Volumen: 83
Número: 197
Paginación: 81-86
País: Colombia
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Aplicado, descriptivo
Resumen en español Operadores humanos responden a alarmas en condiciones normales y también en situaciones inesperadas y anormales en tiempo real. El objetivo de este estudio consiste en aumentar el conocimiento de las reacciones humanas a alarmas en el ámbito laboral. Describe como los humanos pueden contribuir a accidentes y presta atención a la seguridad del proceso que se efectúa en el tiempo de reacción a las alarmas de sistema. Este experimento fue ejecutado para investigar si hay diferencias en respuestas diferenciales a alarmas visuales comparándolas a alarmas auditivas. Los resultados indican que las alarmas visuales son percibidas de manera más eficiente que las alarmas auditivas. Incluso, se pudo ver una correlación negativa entre la cantidad de errores y el tiempo de reacción, lo que indica una diferencia individual en su disposición a errores cuando reaccionan a alarmas visuales en operaciones de supervisión
Resumen en inglés Human operators are required to respond to alarms in normal conditions, and also to find solutions to unexpected situations in real time. The aim of this study is to increase the knowledge of human responses to alarms in the context of occupational situations. It describes how humans contribute to accidents, and pays special attention to the assurance of process safety assurance, which is in part realized by timely reactions to system alarms. An experiment involving an operator´s reaction times to alarm signals was undertaken to investigate whether there are differential responses to visual as opposed to auditory alarms. The findings in the research show that visual alarm indicators are perceived faster than auditory signals. Furthermore, there was a significant negative correlation between the number of errors and reaction time, indicating an individual difference in error-proneness when reacting to visual alarms in a supervisory task
Disciplinas: Ingeniería
Palabras clave: Ingeniería industrial,
Seguridad industrial,
Seguridad de procesos,
Alarmas,
Señales de audio,
Señales visuales,
Error humano,
Tiempo de reacción
Keyword: Engineering,
Industrial engineering,
Industrial safety,
Process safety,
Alarms,
Audio signals,
Visual signals,
Human error,
Reaction time
Texto completo: Texto completo (Ver PDF)