Septic Tank (ST)-Up Flow Anaerobic Filter (UFAF)-Subsurface Flow Constructed Wetland (SSF-CW) systems aimed at wastewater treatment in sma11localities in Colombia



Título del documento: Septic Tank (ST)-Up Flow Anaerobic Filter (UFAF)-Subsurface Flow Constructed Wetland (SSF-CW) systems aimed at wastewater treatment in sma11localities in Colombia
Revista: Revista técnica de la Facultad de Ingeniería. Universidad del Zulia
Base de datos: PERIÓDICA
Número de sistema: 000448026
ISSN: 0254-0770
Autores: 1
1
1
1
Instituciones: 1Universidad Tecnológica de Pereira, Facultad de Ciencias Ambientales, Pereira, Risaralda. Colombia
Año:
Volumen: 29
Número: 3
Paginación: 269-281
País: Venezuela
Idioma: Español
Tipo de documento: Artículo
Enfoque: Experimental aplicado
Resumen en español Se estudiaron modificaciones al conjuntoTanque Septico (1'8), Filtro Anaerób io de Flujo Ascendente (FAFA) , Y Humedales Artificiales de Fluj o Subsuperficia1 (HAFSS) para el tratamient o d e aguas residuales domésticas (ARD) en p equeños municipioS. En primer lugar. se evaluó el emp leo d e medios de soporte de grava y anillos de guadua en FAFAs con tiempos de residen c ia hidráulica (TRI-I) inferiores a 8 horas , tra­tando un efluente de 1'8. Se obtuVieron remocione s de 49.6% ± 2,6 en DQO. de 56,6% :t 2,1 en DB05 y 62,4% ± 2,3 en SST, sin detectars e diferencias estadís t icamente significativas enlTe tratamientos. Como complemento al sistemaTS-FAFA, se evaluaron unidades p iloto de HAFSS (TRH < 1 día)con lechos d e gra­va y are n a . usando 3 especies vegetales de la zona cafete ra colom biana:Typha (Typha sp.). Junco (Juncus sp.) y Jengibr e (ReneaLmia alpina). Se reportaron r emociones de 5 0.6% ± 21.7 n DBO;; y reducciones en indicadores bacterianos inferiores a 2 órdenes logarítmicos, sin encontrarse diferencias significativas. Las tasas de remoción glob a les obtenidas. en t érminos d e DB05, del conjunto TS-FAFA-HAFSS fueron del 80%. Estos resullados s e usaron para optimizar un slslema d e tratamiento de ARD e n u n a localidad co­lombiana
Resumen en inglés Research was done on SepUc Tank (ST). Up Flow Anaerobic Fille r (UFAF) and S ubsurface Flow Con­stru ted Wetlands (SSF-CW) arra n gemenls. aimed at domestlc wastewater (DWW) treatmen t in Colom ­bian small local1ties. UFAF (commonly used as complernen tary treatment for STeffluenls) with hydraullc residence times (HRf) up to 8 hours were evaluated using gravel and bamboo rings as supporting media. Removal efficiencies of 49.6% ± 2.6 of COD. 56.6% ± 2.1 of BODs and 62.4% ± 2.3 ofTSS, were obtained. No significant statistical differences were detected between treatments. Pilots u n its ofSSF-CW with HRI's up to 1 day were evaluated in order to reacb a minimum of80% removal efficiency o n DWW. as established by Colombian legis lation . Typha s p , JWlCUS sp and Renealmia alpina, vegetal s pecies of the Colombian offee-growin g region. were planted in gravel and sand media . The syslem s reached BOD5 removal effi­ciencies of 50.60/0 ± 21. and indlcator bacteria reductions near t o 2 log cy cles. No significant differences in efficiency were a ltained. The BODs rem oval rates e n ountered, in the ST-UFAF-SS F -CW package, during the study allows 8 0%. The results obtained from lhe p resent research were used in scaling-up a DWW trealment system in a small locality in Colombia
Disciplinas: Ingeniería
Palabras clave: Colombia,
Filtros anaeróbicos,
Flujo de liquidos,
Fosa séptica
Keyword: Anaerobic filters,
Colombia,
Liquid flow,
Septic tanks
Texto completo: https://produccioncientificaluz.org/index.php/tecnica/article/view/6031/6019