Comparação entre ventilação controlada a volume e a pressão no tratamento da hipoxemia no período pós-operatório de cirurgia de revascularização do miocárdio



Título del documento: Comparação entre ventilação controlada a volume e a pressão no tratamento da hipoxemia no período pós-operatório de cirurgia de revascularização do miocárdio
Revista: Revista brasileira de anestesiologia
Base de datos: PERIÓDICA
Número de sistema: 000302624
ISSN: 0034-7094
Autores: 1
1


Instituciones: 1Universidade de Sao Paulo, Faculdade de Medicina, Sao Paulo. Brasil
Año:
Periodo: Jul-Ago
Volumen: 53
Número: 4
Paginación: 440-448
País: Brasil
Idioma: Portugués
Tipo de documento: Artículo
Enfoque: Experimental
Resumen en español JUSTIFICATIVA Y OBJETIVOS: Ventilación controlada a presión ha sido utilizada como modalidad ventilatoria de elección en pacientes que desenvuelven hipoxemia importante en el período pos-operatorio de cirugía de revascularización del miocardio. No obstante, no existen estudios mostrando que la ventilación controlada a presión es más efectiva en la reversión de la hipoxemia pos-operatoria que ventilación controlada a volumen. El objetivo de este estudio fue comparar los efectos de ventilación controlada a presión y ventilación controlada a volumen sobre la oxigenación sistémica en pacientes que desenvuelven hipoxemia caracterizada por una relación PaO2/FiO2 menor que 200 en un período pos-operatorio inmediato de cirugía cardíaca. MÉTODO: Sesenta y un pacientes con relación PaO2/FiO2 menor que 200 fueron alocados en un grupo sometido a la ventilación controlada a presión y otro a volumen. El volumen corriente, la frecuencia respiratoria, la relación inspiración/expiración y la presión positiva al final de la expiración fueron las mismas en los dos grupos. Después de la admisión en la UTI y después de períodos de 1 ó 2 horas de ventilación mecánica, la relación PaO2/FiO2 y el shunt pulmonar fueron cuantificados. RESULTADOS: Hubo un aumento significativo en la relación PaO2/FiO2 y una diminución significativa en el shunt pulmonar después de 1 ó 2 horas de ventilación mecánica; sin embargo no fueron observadas diferencias entre las modalidades ventilatorias. CONCLUSIONES: Las modalidades ventilatorias controladas a volumen y presión fueron igualmente eficientes en el tratamiento de la hipoxemia observada en pacientes en el pos-operatorio inmediato de cirugía de revascularización del miocardio, mostrando que la forma de administración del flujo inspiratorio es poco relevante para el tratamiento de la hipoxemia pos-operatoria
Resumen en inglés BACKGROUND AND OBJECTIVES: Pressure controlled ventilation (PCV) has been used as the ventilation mode of choice in coronary artery bypass graft surgery patients who develop severe hypoxemia in the immediate postoperative period. However, there are no evidences showing that pressure controlled ventilation is more effective in reversing postoperative hypoxemia than controlled mandatory ventilation (CMV). This study aimed at comparing the effects of both ventilation modes on systemic oxygenation in cardiac surgery patients who develop hypoxemia characterized by PaO2/FiO2 ratio lower than 200 in the immediate postoperative period. METHODS: Participated in this study 61 consecutive patients with PaO2/FiO2 ratio lower than 200 who were randomly allocated in two groups according to the ventilatory mode (CMV and PCV). Tidal volume, respiratory rate, inspiration/expiration ratio and positive end-expiratory pressure were kept constant throughout the study in both groups. PaO2/FiO2 ratio and pulmonary shunt were obtained 1 or 2 hours after ICU admission. RESULTS: A significant increase in PaO2/FiO2 ratio and a decrease in pulmonary shunt were observed in both groups one or two hours after mechanical ventilation. However, no differences were observed between both ventilatory modes. CONCLUSIONS: Both ventilatory modes were equally effective in reversing hypoxemia observed in the immediate cardiac surgery postoperative period. Results show that inspiratory flow patterns are not relevant in the treatment of post cardiac surgery hypoxemia
Resumen en portugués JUSTIFICATIVA E OBJETIVOS: Ventilação controlada à pressão tem sido utilizada como modalidade ventilatória de eleição em pacientes que desenvolvem hipoxemia importante no período pós-operatório de cirurgia de revascularização do miocárdio. Contudo não existem estudos mostrando que a ventilação controlada à pressão é mais efetiva na reversão da hipoxemia pós-operatória que ventilação controlada a volume. O objetivo deste estudo foi comparar os efeitos de ventilação controlada à pressão e ventilação controlada a volume sobre a oxigenação sistêmica em pacientes que desenvolvem hipoxemia caracterizada por uma relação PaO2/FiO2 menor que 200 no período pós-operatório imediato de cirurgia cardíaca. MÉTODO: Sessenta e um pacientes com relação PaO2/FiO2 menor que 200 foram alocados em um grupo submetido à ventilação controlada a pressão e outro a volume. O volume corrente, a freqüência respiratória, a relação inspiração/ expiração e a pressão positiva ao final da expiração foram as mesmas no dois grupos. Após a admissão na UTI e após períodos de 1 ou 2 horas de ventilação mecânica, a relação PaO2/FiO2 e o shunt pulmonar foram quantificados. RESULTADOS: Houve um aumento significativo na relação PaO2/FiO2 e uma diminuição significativa no shunt pulmonar após 1 ou 2 horas de ventilação mecânica; contudo não foram observadas diferenças entre as modalidades ventilatórias. CONCLUSÕES: As modalidades ventilatórias controladas a volume e pressão foram igualmente eficientes no tratamento da hipoxemia observada em pacientes no pós-operatório imediat
Disciplinas: Medicina
Palabras clave: Cirugía,
Neumología,
Equipo,
Complicaciones postoperatorias,
Ventilación mecánica
Keyword: Medicine,
Pneumology,
Surgery,
Equipment,
Postoperative complications,
Mechanical ventilation
Texto completo: Texto completo (Ver HTML)