Revista: | Materials research |
Base de datos: | PERIÓDICA |
Número de sistema: | 000312475 |
ISSN: | 1516-1439 |
Autores: | Jesuino, G.A1 Ribeiro, L.M.F Nakazato, R.Z Codaro, E.N Hein, L.R. de O |
Instituciones: | 1Universidade Estadual Paulista "Julio de Mesquita Filho", Faculdade de Engenharia, Guaratingueta, Sao Paulo. Brasil |
Año: | 2001 |
Volumen: | 4 |
Número: | 2 |
Paginación: | 63-69 |
País: | Brasil |
Idioma: | Portugués |
Tipo de documento: | Artículo |
Enfoque: | Experimental |
Resumen en inglés | The present work aimed to study the transformation from as-cast structure of the Ti4Al-4V alloy, as a result of the Ti-6Al-4V recycling, after some rapid heat treatments based on martensitic reactions. The effects on mechanical properties were evaluated by Vickers hardness measurements, Charpy and monotonic tensile tests. The corrosion strength was tested by immersion during 4 months in artificial physiological solutions, to evaluate its possible use as a biomaterial. The data pointed to: a) a reduction on corrosion strength for quenching above b transus; b) significant increasing on hardness and mechanical strength; c) a maintenance of impact toughness; d) the corrosion strength for immersion in a NaCl 1%+ NaF 0,1% (m/m) was lower in all conditions, specially for those including heating to 900 °C |
Disciplinas: | Ingeniería |
Palabras clave: | Ingeniería de control, Ingeniería de materiales, Tratamiento, Titanio, Calor, Corrosión, Biomateriales, Resistencia mecánica |
Keyword: | Engineering, Control engineering, Materials engineering, Treatment, Titanium, Heat, Corrosion, Biomaterials, Mechanical resistance |
Texto completo: | Texto completo (Ver HTML) |