Confiabilidade inter e intraexaminador da avaliação postural da cabeça por fotogrametria computadorizada



Título del documento: Confiabilidade inter e intraexaminador da avaliação postural da cabeça por fotogrametria computadorizada
Revista: Fisioterapia e pesquisa
Base de datos: PERIÓDICA
Número de sistema: 000390054
ISSN: 1809-2950
Autores: 1
2
3
4
Instituciones: 1Universidade de Sao Paulo, Escola de Engenharia de Sao Carlos, Sao Carlos, Sao Paulo. Brasil
2Universidade Anhanguera, Faculdade Anhanguera de Bauru, Bauru, Sao Paulo. Brasil
3Universidade Federal de Sao Carlos, Departamento de Fisioterapia, Sao Carlos, Sao Paulo. Brasil
4Universidade de Sao Paulo, Faculdade de Odontologia de Bauru, Bauru, Sao Paulo. Brasil
Año:
Volumen: 21
Número: 1
Paginación: 34-39
País: Brasil
Idioma: Portugués
Tipo de documento: Artículo
Enfoque: Analítico, descriptivo
Resumen en español La literatura acerca de la confiabilidad de la fotogrametría para la evaluación postural cervical es escasa. El objetivo del presente estudio es verificar la confiabilidad inter e intra-examinador de la fotogrametría computadorizada para la evaluación postural de la cabeza en la vista lateral. Veinticinco mujeres jóvenes fueron posicionadas sentadas con la columna erecta y fotografiadas en la vista lateral. Las fotografías fueron importadas por el programa Corel Draw X3 para la evaluación postural mediante fotogrametría computadorizada. Los análisis de confiabilidad intra e inter-examinadores fueron realizadas para los ángulos: cóndilo acromión (ACA), mentón esternón (AME) y Frankfurt (AF). La fotogrametría era realizada por dos examinadores: EA y EB. Para el análisis intra-examinador, el EA hizo la evaluación de las fotos de las participantes dos veces (A1 y A2) para los mismos ángulos un intervalo de tres meses. Para el análisis inter-examinador, el EB evaluó la fotogrametría de los mismos ángulos (B1), la cual se comparó con los datos del EA. Evaluándose el coeficiente de correlación inter-clase (CCI), se observó que hubo una correlación excelente en el análisis intra-examinador (A1 y A2 ) con CCI=1,0 para los ángulos ACA y AME y CCI=0,78 para AF. Hubo una correlación débil en el análisis inter-evaluadores A1 y B1 con un CCI de 0,24 y 0,26 y entre A2 y B1 con CCI de 0,23; 0,27 y 0,00 para los ángulos de la ACA , AME y AF, respectivamente. Se concluye que la fotogrametría es confiable cuando se realiza por el mismo evaluador. La evaluación inter-examinador mostró baja confiabilidad, lo que puede haber sido comprometido por la experiencia reducida experiencia del EB en la aplicación del método
Resumen en inglés Scientific articles about reliability of photogrammetry for cervical spine posture evaluation are infrequent. The aim of the present investigation is to verify intra-and inter-examiner reliability of the computerized photogrammetry method for head postural evaluation in lateral view. Twenty-five young women, between 20 and 30 years old, were positioned seated in an upright position and photographed in lateral view. The photographs were imported to Corel Draw X3 program for postural evaluation by computerized photogrammetry. Analyses of intra-and inter-examiner reliability were performed for the angles: condyle-acromion (ACA), menton-sternum (AME) and Frankfurt (AF). The photogrammetry was performed by two examiners: EA and EB. For intra-examiner analyses, EA assessed the pictures twice (A1 and A2) for the same angles within 3 months. For the inter-examiner analyses EB performed the photogrammetry for the same angles (B1) in order to compare with the data from EA. Using the interclass correlation coefficient (ICC) we observed an excellent correlation in the intra-examiner analysis (A1 and A2) for the angles: ACA and AME (both with ICC=1.0); and AF (ICC=0.78). For the inter-examiner analyses between A1 and B1, it was observed: ACA (ICC=0.24), AME (ICC=0.26) and AF (ICC=0.00). For the comparison between A2 and B1, the ICC values were: 0.23; 0.27 and 0.00, respectively for ACA, AME and AF, classified as weak correlations. In conclusion, the photogrammetry is reliable when performed by the same examiner. The inter-examiner assess showed low reliability, what could have been compromised by the reduced experience of the EB in applying the method
Resumen en portugués A literatura sobre confiabilidade da fotogrametria para avaliação postural cervical é escassa. O objetivo do presente estudo é verificar a confiabilidade inter e intraexaminador da fotogrametria computadorizada para a avaliação postural da cabeça em vista lateral. Vinte e cinco mulheres jovens foram posicionadas sentadas com a coluna ereta e fotografadas em vista lateral. As fotografias foram importadas pelo programa Corel Draw X3 para a avaliação postural por fotogrametria computadorizada. As análises de confiabilidade intra e interexaminadores foram realizadas para os ângulos: côndilo-acrômio (ACA), mento- esternal (AME) e de Frankfurt (AF). A fotogrametria foi realizada por dois examinadores: EA e EB. Para a análise intraexaminadores o EA fez a avaliação das fotos das participantes duas vezes (A1 e A2) para os mesmos ângulos em um intervalo de três meses. Para a análise interexaminadores o EB avaliou a fotogrametria dos mesmos ângulos (B1), que foi comparada com os dados do EA. Avaliando o coeficiente de correlação interclasse (CCI), observamos que houve correlação excelente na análise intraexaminador (A1 e A2) com CCI=1,0 para os ângulos ACA e AME e CCI=0,78 para AF. Houve fraca correlação na análise interavaliadores A1 e B1 com CCI de 0,24 e 0,26 e entre A2 e B1 com CCI de 0,23; 0,27 e 0,00 para os ângulos ACA, AME AF, respectivamente. Conclui-se que a fotogrametria é confiável quando realizada pelo mesmo avaliador. A avaliação interexaminador apresentou baixa confiabilidade, o que pode ter sido comprometida pela reduzida experiência do EB na aplicação do método
Disciplinas: Medicina
Palabras clave: Diagnóstico,
Ortopedia,
Columna cervical,
Fotogrametría,
Reproducibilidad
Keyword: Medicine,
Diagnosis,
Orthopedics,
Cervical column,
Photogrammetry,
Reproducibility
Texto completo: Texto completo (Ver PDF)