The application of polymerized lipid vesicles as colorimetric biosensors for real-time detection of pathogens in drinking water



Título del documento: The application of polymerized lipid vesicles as colorimetric biosensors for real-time detection of pathogens in drinking water
Revista: Electronic journal of biotechnology
Base de datos: PERIÓDICA
Número de sistema: 000358432
ISSN: 0717-3458
Autores: 1
1
1
1
2
3
1
Instituciones: 1Universidad Técnica Federico Santa María, Centro de Biotecnología, Valparaíso. Chile
2Universidad Técnica Federico Santa María, Departamento de Química, Valparaíso. Chile
3Universidad Técnica Federico Santa María, Departamento de Obras Civiles, Valparaíso. Chile
Año:
Volumen: 15
Número: 1
País: Chile
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Experimental, aplicado
Resumen en inglés The inadequate treatments given to the served waste water which are disposal to the rivers and sea coast are the major sources of faecal Microorganisms and enteric bacterial pathogens. They are among the most serious effects of water pollution bringing risks on public health. None of the current methods for detection of pathogens offer real-time on site solutions, are capable of delivering a simple visual detection signal, or can be easily instrumented as an indicator of the presence of a pathogen in water. The use of lipid vesicles incorporating Polydiacetylenes (PDAs) for the development of biosensors for “real-time” detection of pathogens has become an alternative, due to its potential for simple colorimetric response against harmful environmental effectors. However, its actual application in the field has been complicated because lipid vesicles are unable to respond specifically to environmental changes. In this paper, we report several experimental trials leading to improved response in the detection of flagellated pathogens in drinking water. Chromatic biomimetic membranes of TRCDA/DMPC and TRCDA/DMPC/Tryptophan were used in agar and liquid media, which were challenged with different amounts of Escherichia coli and Salmonella typhimurium. In addition, the effect of some divalent cations on the interaction with vesicles TRCDA/DMPC was investigated. The results indicated an improvement in the response times, both visually and quantitatively, through the use of TRIS-EDTA and proper growing conditions for E. coli and Salmonella. With the application of both conditions, it was possible by incubation at 35ºC to promote bacterial growth, therefore avoiding a dramatic effect on the colour change over control samples which may invalidate the test. Our experiments indicated that the minimum bacterial concentration necessary to produce the transition from blue to red on the vesicles as biosensor approaches 108 CFU/ml within 4 hrs, faster than traditional metho
Disciplinas: Biología
Palabras clave: Biotecnología,
Microbiología,
Agua potable,
Análisis microbiológico,
Biosensores,
Vesículas lipídicas,
Detección de bacterias,
Colorimetría
Keyword: Biology,
Biotechnology,
Microbiology,
Drinking water,
Microbiological analysis,
Biosensors,
Lipid vesicles,
Bacterial detection,
Colorimetry
Texto completo: Texto completo (Ver HTML)