Revista: | Brazilian journal of chemical engineering |
Base de datos: | PERIÓDICA |
Número de sistema: | 000308945 |
ISSN: | 0104-6632 |
Autores: | Nobrega, S.W1 Falaguasta, M.C.R2 Coury, J.R |
Instituciones: | 1Universidade Federal de Alagoas, Departamento de Engenharia Quimica, Maceio, Alagoas. Brasil 2Universidade Federal de Sao Carlos, Departamento de Engenharia Quimica, Sao Carlos, Sao Paulo. Brasil |
Año: | 2004 |
Periodo: | Jun |
Volumen: | 21 |
Número: | 2 |
Paginación: | 275-284 |
País: | Brasil |
Idioma: | Inglés |
Tipo de documento: | Artículo |
Enfoque: | Experimental, aplicado |
Resumen en inglés | Performance of a wire-plate electrostatic precipitator in the removal of particles with a wide particle size distribution was evaluated. The experimental rig utilized consisted of a set of three precipitators whose dimensions could be varied. It was observed that precipitator performance increased with an increase in the gap between the collecting plates, which resulted in a substantial increase in energy consumption per volume of cleaned gas. The grade efficiency predicted by correlations from the literature did not match the experimental measurements, and a new correlation is proposed |
Disciplinas: | Química |
Palabras clave: | Ingeniería química, Precipitadores electrostáticos, Limpieza de gas, Recolección de partículas |
Keyword: | Chemistry, Chemical engineering, Electrostatic precipitators, Gas cleaning, Particle collection |
Texto completo: | Texto completo (Ver HTML) |