Validación del Brief Pain Inventory en personas con enfermedad renal crónica



Título del documento: Validación del Brief Pain Inventory en personas con enfermedad renal crónica
Revista: Aquichan
Base de datos: PERIÓDICA
Número de sistema: 000430310
ISSN: 1657-5997
Autores: 1
2
3
4
Instituciones: 1Universidade Atlantica, Oeiras. Portugal
2Universidade Catolica Portuguesa, Instituto de Ciencias de la Salud, Lisboa. Portugal
3Hospital Curry Cabral, Lisboa. Portugal
4Hospital Professor Doutor Fernando Fonseca, Amadora. Portugal
Año:
Periodo: Ene-Mar
Volumen: 17
Número: 1
Paginación: P-P
País: Colombia
Idioma: Español
Tipo de documento: Artículo
Enfoque: Analítico, descriptivo
Resumen en español Objetivo: comprobar las propiedades psicométricas de la versión portuguesa del Brief Pain Inventory, en personas con enfermedad renal crónica sometidas a hemodiálisis. Método: estudio metodológico. La muestra seleccionada está compuesta por 171 personas con enfermedad renal crónica que presentan dolor durante al menos 24 horas y realizan hemodiálisis en dos clínicas de la región de Lisboa, Portugal. Los datos se recogieron entre mayo y junio del 2015. Se evaluaron las siguientes propiedades psicométricas: validez (constructo, convergente y discriminante), confiabilidad (α de Cronbach) y estabilidad (test-retest). Resultados: se obtuvo información que apoya adecuadamente una estructura bifactorial (interferencia del dolor y grado de severidad del dolor), con confiabilidad (α = 0,90 y α = 0,80, respectivamente) y estabilidad. Las medidas registradas están correlacionadas de forma positiva con el afecto negativo, y de forma negativa, con las medidas de calidad de vida, que sustentan la validez concurrente. Se comprobó la existencia de apoyo para la validez predictiva. Conclusiones: las medidas del "grado de severidad del dolor" e "interferencia del dolor" que se obtuvieron a través del Brief Pain Inventory son válidas y reproducibles en personas con enfermedad renal crónica que presentaron dolor en las últimas 24 horas, cuando se utiliza el cuestionario y la entrevista
Resumen en inglés Objective: Verify the psychometric properties of the Portuguese version of the Brief Pain Inventory in persons with chronic kidney disease who are undergoing hemodialysis. Method: This is a methodological study. The selected sample is comprised of 171 persons with chronic kidney disease who experience pain for at least 24 hours and are undergoing hemodialysis at two clinics in Lisbon, Portugal. The data were collected between May and June 2015. The psychometric properties that were evaluated include validity (construct, convergent and discriminant), reliability (Cronbach's α) and stability (test-retest). Results: Information was obtained that adequately supports a bi-factor structure (pain interference and degree of pain severity), with reliability (α = 0.90 and α = 0.80, respectively) and stability. The measures registered correlate positively with the negative effect, and negatively, with measures of quality of life, which support concurrent validity. The existence of support for predictive validity was verified. Conclusions: The "pain severity" and "pain interference" measures obtained with the Brief Pain Inventory are valid and reproducible in persons with chronic kidney disease who experienced pain during the 24 hours before the questionnaire was used and the interview was conducted
Resumen en portugués Objetivos: comprovar as propriedades psicométricas da versão portuguesa do Brief Pain Inventory em pessoas com doença renal crônica submetidas a hemodiálise. Materiais e método: estudo metodológico. A amostra selecionada está composta por 171 pessoas com doença renal crônica que apresentam dor durante, pelo menos, 24 horas e realizam hemodiálise em duas clínicas de Lisboa, Portugal. Os dados foram coletados entre maio e junho de 2015. Foram avaliadas as seguintes propriedades psicométricas: validade (constructo, convergente e discriminante), confiabilidade (Alfa de Cronbach) e estabilidade (teste-reteste). Resultados: obteve-se informação que apoia adequadamente uma estrutura bifatorial (interferência da dor e grau de severidade da dor), com confiabilidade (α = 0,90 e α = 0,80, respectivamente) e estabilidade. As medidas registradas estão correlacionadas de forma positiva com o afeto negativo, e de forma negativa, com as medidas de qualidade de vida, que sustentam a validade concorrente. Comprovou-se a existência de apoio para validade preditiva. Conclusões: as medidas do "grau de severidade da dor" e "interferência da dor" obtidas por meio do Brief Pain Inventory são válidas e reproduzíveis em pessoas com doença renal crônica que apresentaram dor nas últimas 24 horas, quando se utiliza o questionário e a entrevista
Disciplinas: Medicina
Palabras clave: Insuficiencia renal crónica (IRC),
diálisis renal,
dimensión del dolor,
estudios de validación,
psicometría
Keyword: Chronic renal failure (CRF),
renal dialysis,
pain dimension,
validation studies,
psychometry
Texto completo: Texto completo (Ver HTML)