Revista: | Salud pública de México |
Base de datos: | PERIÓDICA |
Número de sistema: | 000367382 |
ISSN: | 0036-3634 |
Autors: | González González, José Gerardo1 Rodríguez Gutiérrez, René1 Lavalle González, Fernando Javier1 González Cantú, Arnulfo1 Taméz Pérez, Héctor Eloy1 González Saldívar, Gerardo1 Villarreal Pérez, Jesús Zacarías1 |
Institucions: | 1Universidad Autónoma de Nuevo León, Hospital Universitario Dr. José Eleuterio González, Monterrey, Nuevo León. México |
Any: | 2013 |
Període: | Sep-Oct |
Volum: | 55 |
Número: | 5 |
Paginació: | 462-468 |
País: | México |
Idioma: | Inglés |
Tipo de documento: | Artículo |
Enfoque: | Analítico, descriptivo |
Resumen en español | Objetivo. Comparar el coeficiente de correlación de concordancia de HbA1c. Material y métodos. Estudio prospectivo en Monterrey, México, de abril a agosto de 2012 para evaluar la medición de la HbA1c. Participaron 38 individuos y se envió la muestra a 7 laboratorios locales y a uno internacional de referencia. Resultados. Se encontró pobre concordancia en 4 de 7 laboratorios, moderada en 2 y una concordancia significativa en uno. Los valores de HbA1c de tres laboratorios fluctuaron más de 1% del laboratorio de referencia en más de 30% de los casos y más de 2% en 10 a 20%. Conclusiones. La estandarización de la HbA1c no está concluida. Los médicos deberían tomar con cautela las recomendaciones de las guías para HbA1c en el diagnóstico o manejo de la diabetes hasta que se implementen los programas de estandarización |
Resumen en inglés | Objective. To compare the concordance correlation coefficient for HbA1c results in an in-field experience. Materials and methods. A prospective study in Monterrey, Mexico from April to August 2012 was conducted to evaluate the day-to-day clinical situation when measuring HbA1c. Blood samples from 38 consecutive patients were sent to seven local laboratories and one international reference laboratory. Results. Poor concordance was found in 4 out of 7 laboratories, moderate in 2 out of 7, and significant in just one. HbA1c values from three laboratories fluctuated more than 1% above or below the reference laboratory in more than 30% of cases, and more than 2% in 10%-20% of subjects. Conclusions. Standardized HbA1c measurement has not occurred worldwide. Physicians should be aware of this issue and be cautious of HbA1c guidelines on diabetes diagnosis or management until proper standardization programs are implemented |
Disciplines | Medicina |
Paraules clau: | Diagnóstico, Salud pública, Metabolismo, Diabetes, Pruebas de laboratorio, Hemoglobina A glucosilada |
Keyword: | Medicine, Diagnosis, Public health, Metabolism, Diabetes, Laboratory tests, Glycosylated hemoglobin A |
Text complet: | Texto completo (Ver HTML) |