Effect of heat transfer on the performance of a thermoelectric heat pump driven by a thermoelectric generator



Título del documento: Effect of heat transfer on the performance of a thermoelectric heat pump driven by a thermoelectric generator
Revista: Revista mexicana de física
Base de datos: PERIÓDICA
Número de sistema: 000340001
ISSN: 0035-001X
Autors: 1
1
1
Institucions: 1Naval University of Engineering, Postgraduate School, Wuhan, Hubei. China
Any:
Període: Ago
Volum: 55
Número: 4
Paginació: 282-291
País: México
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Experimental
Resumen en español En el presente trabajo se propone un modelo de una bomba de calor termoeléctrica controlada por un generador termoeléctrico con transferencia de calor externa irreversible. Se analiza el desempeño de la bomba de calor combinada, la cual obedece a la ley de Newton de transferencia de calor, usando la combinación de termodinámica de tiempo finito y termodinámica fuera de equilibrio. Se obtienen dos formulas analíticas: para la carga de calor y para el coeficiente de desempeño, ambas en función del trabajo de corriente eléctrica. Se realiza una optimización de la posición de la superficie de transferencia de calor entre cuatro intercambiadores para maximizar la carga de calor y el coeficiente de desempeño de la bomba de calor termoeléctrica combinada. Para este mismo fin, se optimiza también la razón entre el número de elementos termoeléctricos del generador y el total. Se analiza, mediante ejemplos numéricos detallados, la influencia entre las posiciones del elemento termoeléctrico y del área de transferencia de calor
Resumen en inglés A model of a thermoelectric heat pump driven by a thermoelectric generator with external heat transfer irreversibility is proposed. The performance of the combined thermoelectric heat pump device obeying Newton's heat transfer law is analyzed using the combination of finite time thermodynamics and non–equilibrium thermodynamics. Two analytical formulae for heating load versus working electrical current, and the coefficient of performance (COP) versus working electrical current, are derived. For a fixed total heat transfer surface area of four heat exchangers, the allocations of the heat transfer surface area among the four heat exchangers are optimized for maximizing the heating load and the COP of the combined thermoelectric heat pump device. For a fixed total number of thermoelectric elements, the ratio of the number of thermoelectric elements of the generator to the total number of thermoelectric elements is also optimized for maximizing both the heating load and the COP of the combined thermoelectric heat pump device. The influences of thermoelectric element allocation and heat transfer area allocation are analyzed by detailed numerical examples. The optimum working electrical currents for maximum heating load and maximum COP at different total numbers of thermoelectric elements and different total heat transfer areas are provided, respectively
Disciplines Ingeniería
Paraules clau: Ingeniería de control,
Ingeniería eléctrica,
Ingeniería mecánica,
Bombas de calor,
Transferencia de calor,
Termodinámica,
Termoeléctricas
Keyword: Engineering,
Control engineering,
Electrical engineering,
Mechanical engineering,
Thermodynamics,
Thermoelectricity,
Heat pumps,
Heat transfer