Trauma abdominal penetrante consecutivo a corrente eletrica industrial



Título del documento: Trauma abdominal penetrante consecutivo a corrente eletrica industrial
Revista: Revista do Colegio Brasileiro de Cirurgioes
Base de datos: PERIÓDICA
Número de sistema: 000186252
ISSN: 0100-6991
Autors: 1

Institucions: 1Fundacao Faculdade Federal de Ciencias Medicas de Porto Alegre, Porto Alegre, Rio Grande do Sul. Brasil
2Hospital de Pronto-Socorro Municipal, Porto Alegre, Rio Grande do Sul. Brasil
Any:
Període: Jul-Ago
Volum: 27
Número: 4
Paginació: 287-291
País: Brasil
Idioma: Portugués
Tipo de documento: Artículo
Enfoque: Caso clínico
Resumen en inglés The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae
Disciplines Medicina
Paraules clau: Cirugía,
Gastroenterología,
Traumatismos,
Abdomen,
Electricidad,
Quemaduras
Keyword: Medicine,
Gastroenterology,
Surgery,
Trauma,
Abdomen,
Electricity,
Burns