Validation of the Comply with Post-Exposure Management Among Health Care Workers Instrument for Brazil



Título del documento: Validation of the Comply with Post-Exposure Management Among Health Care Workers Instrument for Brazil
Revista: Revista da Escola de Enfermagem da USP
Base de datos: PERIÓDICA
Número de sistema: 000403992
ISSN: 0080-6234
Autors: 1
2
2
2
3
Institucions: 1Universidade Federal de Uberlandia, Escola Tecnica de Saude, Uberlandia, Minas Gerais. Brasil
2Universidade de Sao Paulo, Escola de Enfermagem de Ribeirao Preto, Ribeirao Preto, Sao Paulo. Brasil
3Universidade Federal do Rio de Janeiro, Macae, Rio de Janeiro. Brasil
Any:
Període: Dic
Volum: 50
Número: 6
Paginació: 973-981
País: Brasil
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Analítico, descriptivo
Resumen en español Validaren Brasil el instrumentoComply with post-exposure management among health care workers para la enfermería. MÉTODO Estudio metodológico realizado con 137 profesionales de enfermería expuestos a material biológico. Se analizó la existencia de los efectos floor y ceilingy se valoró la fidedignidad por la consistencia interna de los ítems y la estabilidad de la medida (test-retest). Se analizó la validez de constructo por medio del análisis multibrazo-multimétodo. RESULTADO Se verificaronefectos ceiling en dos subescalas. El resultado de la consistencia interna, de cuatro subescalas, varió entre 0,81 y 0,91, resultados considerados satisfactorios, y dos subescalas presentaron resultado insatisfactorio (0,50 y 0,37). La evaluación de la estabilidad de la medida obtuvo resultados positivos con relación a la significación estadística, con valores del Coeficiente de Correlación Intraclase, entre ambas medidas, variando de 0,301 a 0,727; se confirmó la validez de constructo convergente y divergente mediante el análisis multibrazo-multimétodo, excepto la subescala Actitud, la que presentó valores insatisfactorios. CONCLUSIÓN Elinstrumento presenta resultados satisfactorios de validez y fidedignidad, excluyéndose la dimensión Actitud
Resumen en inglés To validate the Comply with post-exposure management among healthcare workersinstrument for Nursing in Brazil. METHOD A methodological study carried out with 137 nursing professionals exposed to biological material. The existence of floor and ceiling effects was analyzed, evaluating reliability by the internal consistency of the items and test-retest reproducibility. The construct validity was analyzed by the multitrait-multi method analysis. RESULTS Ceiling effects were found in two subscales. The result of the internal consistency of four subscales varied between 0.81 and 0.91. The results were considered satisfactory, while two subscales presented an unsatisfactory result (0.50 and 0.37). An evaluation of the measurement stability obtained positive results in relation to the statistical significance, with Intraclass Correlation Coefficient values between the two measurements ranging from 0.301 to 0.727; the validity of a convergent and divergent construct was confirmed by multitrait-multi method analysis, except for the Attitude subscale, which presented unsatisfactory values. CONCLUSION The instrument presents satisfactory results for validity and reliability, except for the Attitude dimension
Disciplines Medicina
Paraules clau: Salud pública,
Salud ocupacional,
Materiales peligrosos,
Agentes biológicos,
Exposición ocupacional,
Enfermeras
Keyword: Medicine,
Public health,
Occupational health,
Hazardous materials,
Biological agents,
Occupational exposure,
Nurses
Text complet: Texto completo (Ver HTML)