Revista: | Revista brasileira de medicina do esporte |
Base de datos: | PERIÓDICA |
Número de sistema: | 000306196 |
ISSN: | 1517-8692 |
Autores: | Frez, Andersom Ricardo1 Ariza, Deborah Ferreira, Jose Roberto Leonel1 Alves, Eder Paulo Belato Breda, Glaucia Ritter Centenaro, Ligia Aline Ueda, Tiago Kijoshi Bertolini, Gladson Ricardo Flor |
Instituciones: | 1Universidade Estadual do Oeste do Parana, Cascavel, Parana. Brasil |
Año: | 2006 |
Periodo: | May-Jun |
Volumen: | 12 |
Número: | 3 |
Paginación: | 150-152 |
País: | Brasil |
Idioma: | Portugués |
Tipo de documento: | Artículo |
Enfoque: | Caso clínico |
Resumen en español | Debido a los efectos terapéuticos, la ultrasonografía se ha convertido en una herramienta indispensable al tratamiento fisioterapéutico de las alteraciones causadas por lesiones y en diversas enfermedades, a pesar de esto su uso en pacientes pediátricos es controversial por los posibles disturbios y daños a la placa epifisaria. El objetivo de este estudio es verificar si la ultrasonografía continua presenta efectos de alteración en la placa de crecimiento de al tibia de conejas. Ocho conejas de la raza Nueva Zelanda con 2 meses de edad fueron sometidas a un tratamiento usando ultrasonografía terapéutica de forma continua con dosis de 1W/cm² en la región lateral de la articulación de la rodilla derecha por 5 min, durante 10 días con 2 días de intervalo después de la 5ª aplicación. La articulación de la rodilla izquierda fue utilizada como control. El análisis histológico reportó una alteración en la espesura del cartílago epifisario, en el lado tratado el tamaño fue de 24,40% mayor del que en el control (p < 0,0001); mientras que el análisis radiológico no presentó ninguna diferencia entre los miembros. Por tanto, se concluye que la ultrasonografía terapéutica en la forma utilizada produce alteraciones histológicas significativas en la espesura del cartílago en el lado tratado, lo que sugiere una aceleración en el metabolismo de la placa |
Resumen en inglés | The therapeutic efficiency of ultrasound has become an indispensable tool of physical therapy treatment in cases of alteration by lesions and in many kinds of sickness. However, in pediatric cases the use of ultrasound is controversial due to possible disturbance and damage to the growth plate. The aim of this study is to find out if the continuous ultrasound presents alteration effects on the growth plate of female rabbits. Eight New Zealand female rabbits with two months of age were tested. They were treated by continuous therapeutic ultrasound with doses of 1 W/cm² in the lateral region of the right knee joint for five minutes, during 10 days, with an interval of two days after five applications. The left knee joint was used as a control. The histological analysis showed an alteration in the thickness of the growth plate on the treated side 24.40% bigger than in the left knee joint of the control (p < 0.0001). On other hand, the radiological analysis did not show any difference between the limbs. The conclusion was that the therapeutic ultrasound produced significant histological alterations in the cartilage thickness on the treated side according to the manner it was used in the experiment. Such fact suggests an acceleration in the growth plate metabolism |
Resumen en portugués | Devido aos efeitos terapêuticos, o ultra-som tem se tornado ferramenta indispensável no tratamento fisioterapêutico de alterações causadas por lesões e em diversas doenças, porém seu uso em pacientes pediátricos é controverso por possíveis distúrbios e danos à placa epifisária. O objetivo deste estudo é verificar se o ultra-som contínuo apresenta efeitos de alteração na placa de crescimento da tíbia de coelhas. Oito coelhas da raça Nova Zelândia com dois meses de idade foram submetidas a um tratamento usando ultra-som terapêutico de forma contínua com dose de 1W/cm² na região lateral da articulação do joelho direito por 5min, durante 10 dias com dois dias de intervalo após a 5ª aplicação. A articulação do joelho esquerdo foi utilizada como controle. A análise histológica mostrou uma alteração na espessura da cartilagem epifisária, sendo que no lado tratado o tamanho foi 24,40% maior do que no controle (p < 0,0001), enquanto a análise radiológica não apresentou diferença entre os membros. Conclui-se que o ultra-som terapêutico na forma utilizada produz alterações histológicas significativas na espessura da cartilagem no lado tratado, sugerindo uma aceleração no metabolismo da placa |
Disciplinas: | Medicina |
Palabras clave: | Fisiología humana, Terapéutica y rehabilitación, Ultrasonografía, Placa epifisiaria, Rodilla, Histología |
Keyword: | Medicine, Human physiology, Therapeutics and rehabilitation, Epiphysis plate, Knee, Ultrasonography |
Texto completo: | Texto completo (Ver HTML) |