Revista: | Journal of the Mexican Chemical Society |
Base de datos: | PERIÓDICA |
Número de sistema: | 000437798 |
ISSN: | 1870-249X |
Autores: | Davarnejad, Reza1 Sarvmeili, Kasra1 Sabzehei, Meysam1 |
Instituciones: | 1Arak University, Faculty of Engineering, Arak. Irán |
Año: | 2019 |
Periodo: | Oct-Dic |
Volumen: | 63 |
Número: | 4 |
País: | México |
Idioma: | Inglés |
Tipo de documento: | Artículo |
Enfoque: | Experimental, aplicado |
Resumen en español | En este artículo se trató un agua residual de “car wash” (CW) con un método amigable con el medioambiente denominado electro-Fenton. Los experimentos fueron realizados para investigar el evecto de cinco variables importantes incluyendo el tiempo de reacción, la densidad de corriente, pH, la relación molar H2O2/Fe2+ y la relación H2O2/agua residual de “car wash” (mL/L) sobre la calidad del agua residual, tales como DQO, DBO, COT, SST, metales pesados, conductividad eléctrica, surfactantes y dureza. Aplicando un diseño “Box-Behnken” (BBD) y la metodología de la superficie de respuesta (RSM por sus siglas en inglés), se determinaron las condiciones de operación optimizadas. Las condiciones optimizadas para DQO (como factro principal medido en el agua y siguiendo protocolos estandarizados) se logra remover el 68.72% a un tiempo de reacción de 75.80 min, con una densidad de corriente de 58.81 mA/cm2, pH 3.02, H2O2/CW de 1.62 mL/L y H2O2/Fe2+ de 3.66 |
Resumen en inglés | In this paper, a car wash wastewater (CW) was treated by an economic and eco-friendly method called electro-Fenton (EF) technique. The experiments were conducted to investigate the effect of five important variables including reaction time, current density, pH, H2O2/Fe2+ molar ratio and H2O2/Car wash wastewater (mL/L) on the quality characteristics of wastewater such as COD, BOD5, TOC, TSS, heavy metals, EC, surfactants and hardness. By applying Box-Behnken design (BBD) and response surface methodology (RSM), the optimum operating conditions were obtained. The optimum conditions for COD [as a main factor in a wastewater (according to the environmental protocols)] removal of 68.72% were experimentally found at reaction time of 75.80 min, current density of 58.81 mA/cm2, pH of 3.02, volume ratio of H2O2/CW of 1.62 mL/L, H2O2/Fe2+ molar ratio of 3.66 |
Disciplinas: | Ingeniería |
Palabras clave: | Ingeniería ambiental, Ingeniería química, Aguas residuales, Oxidación, Electro-Fenton, Calidad del agua |
Keyword: | Environmental engineering, Chemical engineering, Waste water, Car wash wastewater treatment, Electro-Fenton, Water quality |
Texto completo: | Texto completo (Ver HTML) Texto completo (Ver PDF) |