Effects of spongioplasty on neourethral function following hypospadias repair: an experimental study in rabbits



Título del documento: Effects of spongioplasty on neourethral function following hypospadias repair: an experimental study in rabbits
Revista: International braz j urol
Base de datos: PERIÓDICA
Número de sistema: 000434621
ISSN: 1677-5538
Autors: 1
1
1
1
2
Institucions: 1First Affiliated Hospital of Gannan Medical University, Department of Plastic Surgery, Ganzhou, Jiangxi. China
2Beijing Union Medical College, Plastic Surgery Hospital, Beijing. China
Any:
Període: May-Jun
Volum: 46
Número: 3
País: Brasil
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Aplicado, descriptivo
Resumen en inglés Purpose: Spongioplasty (mobilization and midline approximation of the two branches of the bifid dysplastic distal corpus spongiosum) can form a covering layer for the neourethra to prevent urethrocutaneous fistula in hypospadias repair surgery. However, it remains unclear whether spongioplasty affects neourethral function. The objective of this study was to compare neourethral function after hypospadias repair with and without spongioplasty. Materials and Methods: Fourteen congenital hypospadiac New Zealand male rabbits were randomly allocated into two groups, seven animals underwent Duplay hypospadias repair and spongioplasty (experimental group), while seven underwent Duplay surgery alone (control group). Functional differences between groups were assessed by comparing neourethral compliance and flow rate. Two months after surgery, in vivo neourethral compliance was assessed by measuring intraluminal pressure with a digital pressure meter of an isolated neourethral segment, following progressive distension with 1, 2, and 3mL of air. Penises were harvested for uroflowmetry test using a simple device. Results: Postoperatively, fistula developed in one and zero rabbits in the control and experimental groups, respectively. Mean pressures tended to be higher in the experimental group than in the control group (82.14 vs. 69.57, 188.43 vs. 143.26, and 244.71 vs. 186.29mmHg for 1, 2, and 3mL of air, respectively), but the difference was not statistically significant. Mean flow rates also did not significantly differ between the experimental and control groups (2.93mL/s vs. 3.31mL/s). Conclusion: In this congenital rabbit model, no obvious functional differences were found between reconstructed urethras after hypospadias repair with and without spongioplasty
Disciplines Medicina
Paraules clau: Urología,
Cirugía,
Hipospadias,
Fístula uretral,
Cirugía correctiva,
Espongioplastia,
Modelos animales
Keyword: Urology,
Surgery,
Hypospadias,
Urethral fistula,
Corrective surgery,
Spongioplasty,
Animal models
Text complet: Texto completo (Ver HTML) Texto completo (Ver PDF)