Different schematic eyes and their accuracy to the "in vivo" eye: a quantitative comparison study



Título del documento: Different schematic eyes and their accuracy to the "in vivo" eye: a quantitative comparison study
Revista: Brazilian journal of physics
Base de datos: PERIÓDICA
Número de sistema: 000408629
ISSN: 0103-9733
Autors: 1
2
Institucions: 1Universidade Federal de Sao Carlos, Sao Carlos, Sao Paulo. Brasil
2Universidade de Sao Paulo, Instituto de Fisica de Sao Carlos, Sao Carlos, Sao Paulo. Brasil
Any:
Període: Jun
Volum: 37
Número: 2A
Paginació: 378-387
País: Brasil
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Experimental, analítico
Resumen en inglés Current ophthalmic technology allows the manipulation of eye components, such as anterior cornea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulate practically any mechanical or optical characteristic of the product, even before it is thrown into production line. Although quite similar in the general form, different human eye models simulate the image formation by considering different property combinations in the constitutive elements of the eye structure (such as refraction index and surface curvatures), producing retinal images that resemble very closely those of the biological eye. Using optical design software, we have implemented a simulation of 5 well-known schematic eyes available in the literature. These models were the Helmholtz-Laurance, Gullstrand, Emsley, Greivenkamp and Liou & Brennan. The optical performance of these different models was compared using different quantitative optical quality parameters. The model of Liou and Brennan, contains features of the biological eye that were not considered in previous models, as the distribution of a gradient refraction index and a decentered pupil. Furthermore, it has great reliability since it takes into account the mean value of empirical measurements of the in vivo eye in order to define size and parameters such as anterior and posterior curvature of cornea, lens, axial length, etc. Comparisons between the MTF (Modulation Transfer Function), spot diagrams and ray fan showed the difference in image quality between eye models, and the Strehl Ratio was also used as a parameter of comparison. A careful comparison
Disciplines Física y astronomía,
Medicina
Paraules clau: Física,
Optica,
Oftalmología,
Aberraciones ópticas
Keyword: Physics and astronomy,
Medicine,
Optics,
Physics,
Ophthalmology,
Optical aberrations
Text complet: Texto completo (Ver PDF)