Direct and simultaneous spectrophotometric determination of Fe (III) and Ni (II) using salicylaldehyde acetoacetic acid hydrazone - applications



Título del documento: Direct and simultaneous spectrophotometric determination of Fe (III) and Ni (II) using salicylaldehyde acetoacetic acid hydrazone - applications
Revista: Avances en química
Base de datos: PERIÓDICA
Número de sistema: 000355298
ISSN: 1856-5301
Autors: 1
2
3
4
4
Institucions: 1Institute of Technology, Hyderabad, Andhra Pradesh. India
2Foundation for Higher Education, Hyderabad, Andhra Pradesh. India
3Malla Reddy College of Engineering, Hyderabad, Andhra Pradesh. India
4Sri Krishnadevaraya University, Anantapur, Andhra Pradesh. India
Any:
Volum: 5
Número: 3
Paginació: 153-159
País: Venezuela
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Experimental, analítico
Resumen en español Un método espectrométrico rápido, simple y sensible ha sido desarrollado para la determinación de Fe(III) y Ni(II) usando la hidrazona del ácido saliciladehido acetoacético (SAAH) como reactivo cromofórico. Las curvas de calibración lineal fueron obtenidas en cada caso. El método propuesto es aplicado para la determinación simultánea de Fe(III) y Ni(II) empleando su espectros de primer orden. El método está basado en la medición de cruzamiento cero de las amplitudes de la primera derivada. Las amplitudes de la primera derivada a 525 nm y 395 nm obedecen la ley de Beer en el rango de concentración 0,054-0,270 μg/mL y 0,112-0,561 μg/mL para Fe(III) y Ni(II), respectivamente. Un gran número de iones no interfieren en el presente método. El método es usado para la determinación de cantidades micro de Fe(III) y Ni(II) en mezclas de acero y en mezclas sintéticas
Resumen en inglés A rapid, simple and sensitive spectrophotometric method has been developed for determination of Fe (III) and Ni (II) using salicylaldehyde acetoacetic acid hydrazone (SAAH) as a chromophoric reagent. The linear calibration ranges were obtained in each case. The proposed method is applied for the simultaneous determination of Fe (III) and Ni (II) utilizing their first order spectra. The method is based on the zero crossing measurement of first derivative amplitudes. The first derivative amplitudes at 525 nm and 395 nm obey Beer's law in the concentration range 0.054-0.270 μg/mL and 0.112-0.561 μg/mL for Fe (III) and Ni (II) respectively. A large number of foreign ions do not interfere in the present method. The method is used for the determination of micro amounts of Fe (III) and Ni (II) in alloy steels and in synthetic mixtures
Disciplines Química
Paraules clau: Química analítica,
Espectrofotometría,
Fierro,
Níquel,
Hidrazona,
Acido saliciladehido acetoacético (SAAH),
Reactivo cromofórico
Keyword: Chemistry,
Analytical chemistry,
Spectrophotometry,
Iron,
Nickel,
Hydrazone,
Salicylaldehyde acetoacetic acid (SAAH),
Chromophoric reagent
Text complet: Texto completo (Ver PDF)